Chapter 4 Basic Operations of the RM-3348HR Remote Control Unit
4-21
Chapter 4
Saving time values directly in the IN and
OUT-point registers
In continuous auto punch mode, you can directly save
punch-in and punch-out points in any desired register
pair by specifying the number (1 through 9) of the
registers.
1
Enter the time value for the punch-in point on the
LOCATE TIME display using the numeric buttons.
2
Press and light the STORE button, then press the
IN button.
The STORE button goes off and “In” is displayed
on the lower CUE display.
3
Enter the time value for the punch-out point on the
LOCATE TIME display using the numeric buttons.
4
Press and light the STORE button, then press the
OUT button.
The STORE button goes off and “ou” is displayed
on the lower CUE display.
5
Press and light the STORE button, then enter the
number of the target registers on the upper CUE
display.
The STORE button goes off, and the time values
specified in steps
1
and
3
are saved in the IN/OUT-
point registers of the numbers specified in step
5
.
Notes
•
If you specify a section that overlaps a section already
saved in another register, “O.V.L. (overlap)” appears
on the LOCATE TIME display and saving is not
executed.
•
When “O.V.L.” is displayed, check the registered
punch-in/out points as necessary (see “Checking the
registered punch-in/out points” below) and save other
points.
The “O.V.L.” indication is cleared when a new point
is saved or by your pressing the CLEAR button.
•
Even if punch-in and punch-out points have already
been saved in the specified register, the newly
specified points are saved when you execute step
5
.
•
Continuous auto punch in/out is executed
automatically in the order of the punch-in points. The
order of the punch-in points need not correspond to
the order of the registers.
Checking the registered punch-in/out
points
To check the punch-in/out points that have been saved
in each register pair, proceed as follows.
1
Press and light the RECALL button, then enter the
desired register number using the numeric buttons.
The RECALL button goes off and the saved
punch-in point is displayed on the time data
display.
2
Press and light the RECALL button, then press the
OUT button.
The RECALL button goes off and the corresponding
punch-out point is displayed in place of the punch-
in point.
Repeat steps
1
and
2
for all the registers to be checked.
When checking is completed, press the CLEAR button.
TAPE TIME
CUE
DF
LOCATE TIME
CTL
TIME CODE
RELATIVE
ABSOLUTE
TIMER
CUE
H
MIN
SEC
H
MIN
SEC
mSEC
SF
FRAME
Register number (example: register 2)
Registered punch-in point (example: 10 min. 40 sec.)
Registered punch-out point (example: 10 min. 30 sec.)
TAPE TIME
CUE
DF
LOCATE TIME
CTL
TIME CODE
RELATIVE
ABSOLUTE
TIMER
CUE
H
MIN
SEC
H
MIN
SEC
mSEC
SF
FRAME
Summary of Contents for PCM-3348HR
Page 8: ...1 2 Chapter 1 Overview Chapter 1 ...
Page 86: ...4 32 Chapter 4 Basic Operations of the RM 3348HR Remote Control Unit Chapter 4 ...
Page 114: ...5 28 Chapter 5 Time Shift Editing Using the Sound Memory Chapter 5 ...
Page 126: ...6 12 Chapter 6 Digital Copy Chapter 6 ...
Page 142: ...7 16 Chapter 7 Synchronized Operations Chapter 7 ...
Page 172: ...10 16 Chapter 10 External Synchronization Chapter 10 ...