1-21
MVS-8000A/8000ASF
D3700 (A-4) :
+
+
+
+
+
12 V
+
12 V power supply status indication.
Lit when the
+
12 V power is supplied.
If this LED does not light, the fuse may have blown.
D3701 (A-5) :
+
+
+
+
+
1.8 V
+
1.8 V power supply status indication.
Lit when the
+
1.8 V power is supplied.
D3702 (A-5) :
+
+
+
+
+
2.5 V
+
2.5 V power supply status indication.
Lit when the
+
2.5 V power is supplied.
D3703 (A-4) :
+
+
+
+
+
3.3 V
+
3.3 V power supply status indication.
Lit when the
+
3.3 V power is supplied.
A side/Component side
IF-937
A
B
C
D
E
F
G
D2703
D2702
D2701
D2700
S2700
1
2
3
4
5
6
7
8
9
10
11
12
13
D3700
S2300
S2301
D3703
1
2
3
4
5
DI1
DI4
SW1
SW2
A
B
C
D
E
F
DI8 DI7 DI6 DI3 DI2
CPU-DK
Module
D3702
D3701
A
B
C
D
E
F
G
D2701
D2702
D2703
D2700
S2700
1
2
3
4
5
6
7
8
9
10
11
12
13
D3700
S2300
S2301
D3703
1
2
3
4
5
DI1
DI4
SW1
SW2
A
B
C
D
E
F
DI8 DI7 DI6 DI3 DI2
CPU-DK
Module
D3702
D3701
3. DIF-141 board (MKS-8170M)
<LED>
D2700 (A-7) : CONF ERR status LED
FPGA (EP20K100E and Spartan II) CONFIG DONE
status indication.
Not lit when all configurations are completed.
D2701 (B-7), D2702 (B-6), D2703 (B-6)
(Board suffix-11) : MAIN CPU status LED
Main CPU status indication.
D2701, D2702, D2703 (A-8) (Board suffix-12) :
MAIN CPU status LED
Main CPU status indication.
Board suffix : -11
Board suffix : -12