1-31
MVS-8000A/8000ASF
1-8-2. Checks on the Switch Setting the Number of Power Supply Units
Before turning on the power of the MVS-8000A/8000ASF, confirm that the switch S403 on the CA-54A
board is set in the following position (default setting).
S403 (B-1)/CA-54A board : Switch setting the number of power supply units (DIP type)
Sets the number of the power units required for the MVS-8000A/8000ASF.
.
MVS-8000A (Serial No. 10001 to 10010)
S403-1 : OFF
S403-2 : OFF
S403-3 : ON
S403-4 : OFF
.
MVS-8000A (Serial No. 10011 and Higher)
MVS-8000ASF (Serial No. 10001 and Higher)
S403-1 : ON
S403-2 : ON
S403-3 : OFF
S403-4 : OFF