3. Camera Operations: User Functions Screen
52
Assignable Button
setting
Function
State after rebooting
Iris Open (1/16 stop)
7)
Opens the lens iris.
Press and hold to open the iris until fully
open.
This function is available when an E-mount
lens with power iris is attached.
The setting is in 1/16 stop increments,
whereas the iris indication is in units of 1/3
stop increments.
–
Iris Close (1/16 stop)
7)
Closes the lens iris.
Press and hold to close the iris until fully
closed.
This function is available when an E-mount
lens with power iris is attached.
The setting is in 1/16 stop increments,
whereas the iris indication is in units of 1/3
stop increments.
–
1) Does not function if the button is pressed when Technical > Special Configuration > RM/RCP Paint Control
(page 91) is set to On in the full menu.
2) Also applied to the HDMI output if the HDMI output has the same output format as the Monitor output. You can
check the setting using Monitoring > Overlays/Frame Line > HDMI (page 79) in the full menu. The HDMI output is
the same as the Monitor output if HDMI is set to “Same as Monitor”.
3) If the SDI output format is 1920×1080i, the focus magnifier function is off, and pressing the button performs no
function.
4) Switches to the same image as the main signal that is selected using Project > Basic Setting > Input Color Space
(page 72) in the full menu while the button is pressed.
5) Does not function if the button is pressed when an RM-B170 or other remote control unit is connected and
Technical > Special Configuration > RM/RCP Paint Control (page 91) is set to On in the full menu.
6) When Technical > Special Configuration > RM/RCP Paint Control (page 91) is set to On and Shooting > LUT Select
> VF LUT (page 70) is set to R709(800%) or R709-Like in the full menu, this switches to the same image as the
main signal while the button is pressed. When RM/RCP Paint Control is set to Off and VF LUT is not set to Log, this
switches to the same image as the main signal while the button is pressed.
7) Does not function if the button is pressed when an RM-B170 or other remote control unit is connected.
8) Does not function if the button is pressed when Monitoring > Output Display > Flip Image (page 77) > H & V Flip
in the full menu is grayed out.
Functions that can be Assigned to Viewfinder (DVF-EL200) Assignable
Buttons A to C
Assignable Button
setting
Function
State after rebooting
No Assign
No assignment
–
VF Frame Line
Turns superimposition of frame lines on the
viewfinder/monitor screen output image on/
off.
Setting retained
VF Overlay
Turns the information display on the
viewfinder/monitor screen output image on/
off.
Setting retained
Press & Hold for VF
Log
2)
Disables the LUT applied to the viewfinder/
monitor screen output image while the
button is pressed for normal image quality
without applying a LUT.
Setting not retained
VF Focus Magnifier
Turns the focus magnifier function of the
viewfinder on/off.
Setting not retained
VF Highlight Clip Ind
3)
Turns the function to display clipped highlight
areas in red in the viewfinder on/off.
Setting retained
VF High/Low Key
3)
Selects the viewfinder output mode.
Switches between High Key (screen for
checking for blown-out highlights)
Low
Key (screen for checking for blocked-out
shadows)
Off (normal display) each time
the button is pressed.
Setting not retained
VF False Color
3)
Turns the false color function display in a
viewfinder on/off.
Setting retained
VF Zebra
Turns the zebra function of the viewfinder/
monitor screen output image on/off.
Setting retained
Line A: Aspect Ratio
Disp.
Turns the Aspect Ratio display for Line A on/
off.
Setting retained
Line B: Aspect Ratio
Disp.
Turns the Aspect Ratio display for Line B on/
off.
Setting retained
Line A: User Frame
Disp.
Turns the User Frame Line 1 and User Frame
Line 2 display for Line A on/off.
Each time the button is pressed, the display
switches between User Frame Line 1 and 2
display
User Frame Line 1 display
User
Frame Line 2 display
User Frame Line 1 and
2 hidden.
Setting retained