![Sony MB-806A Service Manual Download Page 42](http://html.mh-extra.com/html/sony/mb-806a/mb-806a_service-manual_415884042.webp)
3-16
MB-806A (CE)
WRU-806A (CE, AU)
(4) Turn on and off the MODULATION (modulation
frequency) of the signal generator as follows, and
check that BATT Indicator (Tuner
[1]
) change also as
follows:
MODULATION setting BATT indicator of Tuner
[1]
[1]
[1]
[1]
[1]
of signal generator
ON
BATT indicator (LCD);
Turn the signal
generator on and BATT
indicator starts blinking
after 30 seconds.
BATT indicator (LED);
Turn the signal
generator on and BATT
indicator starts blinking
after 30 seconds.
OFF
BATT indicator (LCD);
Goes out.
BATT indicator (LED);
Goes out.
(5) Connect the signal generator to the ANTENNA B IN
connector with DC cut fixture, and perform the
procedures (3) and (4) above.
Step 2:
Tuner
[2]
to Tuner
[6]
checking
When the WRU-806A Tuner Unit is installed in the Tuner
[2]
(Tuner unit 2) to Tuner
[6]
(Tuner unit 6) of the MB-
806A, perform the adjustments from procedures (1) to (4)
of “Step 1. Tuner
[1]
(Tuner unit 1) checking” on the
respective tuner units that are installed in the MB-806A.
When performing the above described checking change the
following details as shown below, of the “Step 1. Tuner
[1]
(Tuner unit 1) checking”.
Tuner
[1]
→
Tuner
[2]
,
[3]
,
[4]
,
[5]
, and
[6]
8. BATT (Battery) indicator check
Procedure
Step 1:
Tuner
[1]
(Tuner unit 1) checking
n
The checking procedures describe that the WRU-806A (to
be adjusted) is installed into the Tuner
[1]
slot on the MB-
806A.
(1) Set the MB-806A as follows;
Front panel (Tuner
[1]
)
Channel setting:
CE62 model; Group 00, 6301 channel (806.125 MHz)
CE69 model; Group 00, 6933 channel (858.125 MHz)
AU66 model; Group00, 6701 channel (799.250 MHz)
Muting: ON (Normal mode)
Rear panel
ATT (ANTENNA A, B) switch: 0 dB
(2) Connect the signal generator to the ANTENNA A IN
connector with DC cut fixture.
(3) Set the signal generator as follows:
Signal generator setting
FREQUENCY(carrier frequency):
CE62 model; 806.125 MHz
CE69 model; 858.125 MHz
AU66 model; 799.250 MHz
RF OUTPUT (Output level): 60 dB
u
V
EMF
(=
_
53 dBm)
MODULATION (Modulation frequency):
32.782 kHz
(32.782 kHz must be set
by connecting Function
generator)
DEVIATION (Frequency deviation):
±
2.1 kHz
AF
BATT
AF
BATT
Summary of Contents for MB-806A
Page 22: ......
Page 26: ......
Page 44: ......
Page 68: ......
Page 72: ...7 2 MB 806A CE WRU 806A CE AU 7 2 MB 871 MB 871 MB 871 A SIDE 1 674 361 11 ...
Page 73: ...7 3 MB 806A CE WRU 806A CE AU 7 3 MB 871 MB 871 MB 871 B SIDE 1 674 361 11 ...
Page 82: ......