![Sony MB-806A Service Manual Download Page 35](http://html.mh-extra.com/html/sony/mb-806a/mb-806a_service-manual_415884035.webp)
3-9
MB-806A (CE)
WRU-806A (CE, AU)
Connection
1. Output level check
Procedure
Step 1:
Tuner
[1]
(Tuner unit 1) checking
n
The checking procedures describe that the WRU-806A(to
be adjusted) is installed into the Tuner
[1]
slot on the MB-
806A.
(1) Set the MB-806A as follows;
Front panel (Tuner
[1]
)
FREQUENCY(carrier frequency):
Channel setting:
CE62 model; Group 00, 6301 channel (806.125 MHz)
CE69 model; Group 00, 6933 channel (858.125 MHz)
AU66 model; Group00, 6701 channel (799.250 MHz)
Muting: OFF
Rear panel
ATT (ANTENNA A, B IN) switch: 0 dB
OUTPUT LEVEL switch:
_
20 dBm (LINE)
(2) Connect the audio analyzer to the TUNER OUTPUT 1
connector via MIC amp.
(3) Connect the signal generator to the ANTENNA A IN
connector with DC cut fixture.
1
2
3
4
5
6
Signal
generator
Audio
analyzer
MIC amp
600
Z
balance
input
DC cut fixture
ANTENNA
A IN
Oscilloscope
DC cut fixture
ANTENNA B IN
MB-806A
Tuner
WRU-806A
Function
generator
TUNER
OUTPUT 1
(4) Set the signal generator as follows:
Signal generator setting
CE62 model; 806.125 MHz
CE69 model; 858.125 MHz
AU66 model; 799.250 MHz
RF OUTPUT (Output level): 60 dB
u
V
EMF
(=
_
53 dBm)
MODULATION (Modulation frequency): 1 kHz
DEVIATION (Frequency deviation):
±
5 kHz
(5) Check that the TUNER OUTPUT 1 connector output
level is
_
21 dBm
±
1.5 dB (at 600
Z
loaded).
(6) Connect the audio analyzer to the MIX OUTPUT
connector via MIC amp.
(7) Check that the MIX OUTPUT connector output level
is
_
21 dBm
±
1.5 dB (at 600
Z
loaded).
(8) Set the MIX OUTPUT LEVEL switch is
_
58 dBm
(MIC).
(9) Check that the TUNER OUTPUT 1 connector output
level is
_
59 dBm
±
1.5 dB. (at 600
Z
loaded)
(10)Check that the MIX OUTPUT connector output level
is
_
59 dBm
±
1.5 dB (at 600
Z
loaded).
(11)Connect the signal generator to the ANTENNA B IN
connector, and perform the procedures (4) to (10)
above.
Step 2:
Tuner
[2]
to
[6]
checking
When the WRU-806A Tuner Unit is installed in the Tuner
[2]
(Tuner unit 2) to Tuner
[6]
(Tuner unit 6) of the MB-
806A, perform the adjustments from procedures (1) to (11)
of “Step 1. Tuner
[1]
(Tuner unit 1) checking” on the
respective tuner units that are installed in the MB-806A.
When performing the above described checking change the
following details as shown below, of the “Step 1. Tuner
[1]
(Tuner unit 1) checking”.
Tuner
[1]
→
Tuner
[2]
,
[3]
,
[4]
,
[5]
, and
[6]
TUNER OUTPUT 1
→
TUNER OUTPUT 2, 3, 4, 5, and 6
Summary of Contents for MB-806A
Page 22: ......
Page 26: ......
Page 44: ......
Page 68: ......
Page 72: ...7 2 MB 806A CE WRU 806A CE AU 7 2 MB 871 MB 871 MB 871 A SIDE 1 674 361 11 ...
Page 73: ...7 3 MB 806A CE WRU 806A CE AU 7 3 MB 871 MB 871 MB 871 B SIDE 1 674 361 11 ...
Page 82: ......