5-25
18. Strobe White Balance Adjustment
Adjust the white balance when the strobe light flashes.
Mode
STILL
Subject
A plate which reflection rate is 18 %
(1.0m from the front of the lens)
Adjustment Page
F
Adjustment Address
4D, 4E, 64, 69, 6A, 6B
Note 1:
Perform this adjustment in the dark room or use a dark box.
Note 2:
Any light other than the strobe light should not light up the plate.
Note 3:
This adjustment should be carried out upon completion of “HALL
Adjustment”, “Flange Back Adjustment”, “Light Level
Adjustment” and “Auto White Balance Adjustment”.
Note 4:
After the power is turned on, this adjustment can be done only
once.
Switch setting:
1)
FLASH .............................................................................. ON
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 6, address: 90, and set data: 00.
3)
Select page: 6, address: 91, and set data: 00.
4)
Select page: 6, address: 92, and set data: 00.
5)
Select page: 6, address: 93, and set the following data.
80 : MVC-FD85
60 : MVC-FD90
6)
Select page: 6, address: 6C, and set data: 01.
7)
Select page: 6, address: 2C, and set data: 01.
8)
Select page: 6, address: 01, set data: 79, and press the PAUSE
button.
9)
Select page: 6, address: 01, set data: 67, and press the PAUSE
button. (Check the flashing of the strobe light.)
10) Select page: 6, address: 01, set data: 00, and press the PAUSE
button.
11) Select page: 6, address: 01, set data: 79, and press the PAUSE
button.
12) Select page: 6, address: 01, set data: 67, and press the PAUSE
button. (Check the flashing of the strobe light.)
13) Select page: 6, address: 01, set data: 00, and press the PAUSE
button.
14) Select page: 6, address: 01, set data: 79, and press the PAUSE
button.
15) Select page: 6, address: 01, set data: B9, and press the PAUSE
button.
16) Check the flashing of the strobe light.
(The strobe white balance adjustment is performed and the
adjustment data is stored in page: F, address: 4D, 4E, 64, 69,
6A and 6B.)
17) Select page: 6, address: 02, and check that the data is “01”.
Processing after Completing Adjustments:
1)
Select page: 6, address: 2C, and set data: 00.
2)
Select page: 6, address: 93, and set data: 00.
3)
Select page: 6, address: 01, set data: 00, and press the PAUSE
button.
4)
Select page: 6, address: 6C, and set data: 00.
5)
Select page: 0, address: 01, and set data: 00.
19. Strobe Light Level and White Balance Check
Check the light level regulation and the white balance when the
strobe light flashes.
Mode
STILL
Subject
A plate which reflection rate is 18%
(1.0 m from the front of the lens)
(Note 1)
Measurement Point
Display data of page: 1
Measuring Instrument
Adjustment remote commander
Specified value
Y level data: 60 to 94 (Note 4)
R-Y data: FA to FF or 00 to 06
(Note 5)
B-Y data: FA to FF or 00 to 06
(Note 5)
Note 1:
Perform this adjustment in the dark room or use a dark box.
Note 2:
Any light other than the strobe light should not light up the plate.
Note 3:
This adjustment should be carried out upon completion of “HALL
Adjustment”, “Flange Back Adjustment”, “Light Level
Adjustment”, “Auto White Balance Adjustment” and “Strobe White
Balance Adjustment”.
Note 4:
Display data of pag: F, address: 64 of the adjustment remote
commander.
F : XX : 64
Y level data
Note 5:
Display data of page 1 of the adjustment remote commander.
1 : XX : XX
B-Y data
R-Y data
Switch setting:
1)
FLASH .............................................................................. ON
Checking method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 6, address: 90, and set data: 00.
3)
Select page: 6, address: 91, and set data: 00.
4)
Select page: 6, address: 92, and set data: 00.
5)
Select page: 6, address: 93, and set the following data.
80 : MVC-FD85
60 : MVC-FD90
6)
Select page: 6, address: 6C, and set data: 01.
7)
Select page: 6, address: 2C, and set data: 01.
8)
Select page: 6, address: 01, set data: 79, and press the PAUSE
button.
9)
Select page: 6, address: 01, set data: 67, and press the PAUSE
button.
10) Check the flashing of the strobe light.
11) Select page: F, address: 64, and check that the Y level data
satisfies the specified value. (Note4)
12) Select page: 0, address: 03, and set data: 02.
13) Select page: 1, and check that the R-Y data and B-Y data satisfy
the specified value respectively.(Note5)
Processing after Completing Adjustments:
1)
Select page: 0, address: 03, and set data: 00.
2)
Select page: 6, address: 2C, and set data: 00.
3)
Select page: 6, address: 93, and set data: 00.
4)
Select page: 6, address: 01, set data: 00, and press the PAUSE
button.
5)
Select page: 6, address: 6C, and set data: 00.
6)
Select page: 0, address: 01, and set data: 00.
Summary of Contents for Mavica MVC-FD85
Page 7: ...1 1 MVC FD85 FD90 SECTION 1 GENERAL This section is extracted from instruction manual ...
Page 8: ...1 2 ...
Page 9: ...1 3 ...
Page 10: ...1 4 ...
Page 11: ...1 5 ...
Page 12: ...1 6 ...
Page 13: ...1 7 ...
Page 14: ...1 8 ...
Page 15: ...1 9 ...
Page 16: ...1 10 ...
Page 17: ...1 11 ...
Page 18: ...1 12 ...
Page 19: ...1 13 ...
Page 20: ...1 14 ...
Page 21: ...1 15E ...
Page 40: ...MVC FD85 FD90 4 33 4 34 AV OUT KEY IN BACK LIGHT RGB TG PK 50 ...
Page 42: ...MVC FD85 FD90 4 37 4 38 AV OUT KEY IN BACK LIGHT RGB TG PK 52 ...