5-17
5. Flange Back Check
Mode
STILL
Subject
Siemens star
(2.0 m from the front of the lens)
(Luminance : approx. 200 lux)
Measurement Point
Check operation on TV monitor
Measuring Instrument
Specified Value
The lens is focused.
Switch setting:
1) FOCUS .................................................... AUTO (MVC-FD90)
.... AUTO (No mark indicated on LCD) (MVC-FD85)
Checking method:
1)
Place the Siemens star 2.0m from the front of the lens.
2)
To open the IRIS, decrease the luminous intensity to the
Siemens star up to a point before noise appear on the image.
3)
Shoot the Siemens star with the zoom TELE end.
4)
Select page: 5, address: F1, and set data: FF.
5)
Observe the TV monitor and check that the lens is focused.
6)
Select page: 6, address: 2C, and set data: 01.
7)
Shoot the Siemens star with the zoom WIDE end.
8)
Observe the TV monitor and check that the lens is focused.
Processing after Completing Adjustments:
1)
Select page: 6, address: 2C, and set data: 00.
2)
Select page: 5, address: F1, and set data: 00.
6. F No. Standard Data Input
Compensate the unevenness of the iris meter sensitivity.
Mode
STILL
Subject
Clear chart
(Color reproduction adjustment
frame)
Adjustment Page
F
Adjustment Address
29 to 2C
Note 1:
If the data of page: 6, address: 02 is “01”, select page: 6, address:
01, set data: 00, and press the PAUSE button.
Note 2:
After the power is turned on, this adjustment can be done only
once.
Adjusting method:
1)
Shoot the clear chart with the zoom WIDE end.
2)
Select page: 0, address: 01, and set data: 01.
3)
Select page: 6, address: 01, set data: BB, and press the PAUSE
button of the adjustment remote commander.
(The F No. standard data input is performed and the adjustment
data is stored in page: F, address: 29 to 2C.)
4)
Select page: 6, address: 02, and check that the data is “01”.
Processing after Completing Adjustments:
1)
Select page: 6, address: 01, set data: 00, and press the PAUSE
button.
2)
Select page: 0, address: 01, and set data: 00.
7. Mechanical Shutter Adjustment
Adjust the period which the mechanical shutter is closed, and
compensate the exposure.
Mode
STILL
Subject
Clear chart
(Color reproduction adjustment
frame)
Adjustment Page
F
Adjustment Address
5A, 6C to 7F
Note: 1
If the data of page: 6, address: 02 is “01”, select page: 6, address:
01, set data: 00, and press the PAUSE button.
Note: 2
Install the clear chart at a distance of about 10 cm from the front
of the lens. (It is recommended.)
Adjusting method:
1)
Shoot the clear chart with the zoom WIDE end.
2)
Select page: 0, address: 01, and set data: 01.
3)
Select page: 6, address: 01, set data: AD, and press the PAUSE
button of the adjustment remote commander.
(The mechanical shutter adjustment is performed and the
adjustment data is stored in page: F, address: 5A, 6C to 7F.)
4)
Select page: 6, address: 02, and check that the data changes to
“01”.
Processing after Completing Adjustments:
1)
Select page: 6, address: 01, set data: 00, and press the PAUSE
button.
2)
Select page: 0, address: 01, and set data: 00.
Summary of Contents for Mavica MVC-FD85
Page 7: ...1 1 MVC FD85 FD90 SECTION 1 GENERAL This section is extracted from instruction manual ...
Page 8: ...1 2 ...
Page 9: ...1 3 ...
Page 10: ...1 4 ...
Page 11: ...1 5 ...
Page 12: ...1 6 ...
Page 13: ...1 7 ...
Page 14: ...1 8 ...
Page 15: ...1 9 ...
Page 16: ...1 10 ...
Page 17: ...1 11 ...
Page 18: ...1 12 ...
Page 19: ...1 13 ...
Page 20: ...1 14 ...
Page 21: ...1 15E ...
Page 40: ...MVC FD85 FD90 4 33 4 34 AV OUT KEY IN BACK LIGHT RGB TG PK 50 ...
Page 42: ...MVC FD85 FD90 4 37 4 38 AV OUT KEY IN BACK LIGHT RGB TG PK 52 ...