Cha
p
te
r 3
P
rep
a
ra
tions
3-4 Setup
3-33 (E)
325
BI
MAVE-F555 EXT VTR
CONTROL
Specifies edit parameters when an external VTR is selected as the Recorder in the BVE
mode.
SUB MENU
EDIT DELAY
Specifies EDIT DELAY of the external VTR
.. 9 frame
EDIT PRESET COMMEND
Specifies whether Audio Analog Channel 2 is used or Digital Audio Channel 4 is used in
the EDIT PRESET command.
: Digital Audio Channel 4 is used.
Analog
: Analog Audio Channel 2 is used and Audio Channel 3 or 4 selections are
ignored.
UB BYTE 1
UB BYTE 2
UB BYTE 3
UB BYTE 4
Specifies the value of the user bit to specify the VTR during editing.
to FF
349
350
351
BI
REFERENCE SELECT R1
REFERENCE SELECT R2
REFERENCE SELECT R3
Selects the reference signal for the recorder port.
: Selects the output signal as the reference.
Input video : Selects the input signal as the reference.
Notes:
• Changes in settings do not become effective until any file on the recorder
port is unloaded.
• In SS mode, set to output ref.
352
353
354
BI
REC INHIBIT R1
REC INHIBIT R2
REC INHIBIT R3
These items prohibit port recording.
: REC INHIBIT OFF (recording enabled)
REC INHIBIT on
: REC INHIBIT ON (recording prohibited)
401
402
403
BI
FUNCTION MODE AFTER
CUEUP P1
FUNCTION MODE AFTER
CUEUP P2
FUNCTION MODE AFTER
CUEUP P3
These items select the mode to be in effect for the MAV-555SS after the cue-up
operation is completed.
: Set stop mode.
still
: Set still mode (search mode).
404
405
406
BI
VIDEO OUTPUT AFTER
UNLOAD P1
VIDEO OUTPUT AFTER
UNLOAD P2
VIDEO OUTPUT AFTER
UNLOAD P3
These items specify whether to output the last picture or use “BLACK MUTING” after a
file is closed.
: Black Muting.
pb
: Output the last picture.
630
631
632
ID CODE R1
ID CODE R2
ID CODE R3
Sets the ID CODE.
SUB MENU
BYTE 0
BYTE 1
BYTE 2
BYTE 3
.. 0×FF
633
634
635
BI
TCG MODE R1
TCG MODE R2
TCG MODE R3
Sets the Time Code Generator.
SUBMENU
ID CODE PRESET
Sets whether the ID CODE is registered.
: Registers the USER BIT without registering the ID CODE.
ID CODE
: Registers the ID CODE.
REGEN MODE
Selects the regenerate signal when the Time Code Generator is in the regenerate mode.
: Only TC is regenerated.
UB
: Only UB is regenerated.
TC & UB
: Regenerates TC and UB.
REGEN / PRESET
Sets whether Time Code Generator regenerates.
REGEN
: Regenerates the time code.
: Does not regenerate the time code.
Expansion menu items (Continued)
Item number Display indication
Settings
Description
0
Digital
00
output ref
REC INHIBIT off
stop
black
0×00
USER BIT
TC
PRESET