5-55 (E)
Digital Cinema Dual System
5-14. Other
Settings
5-14-1. Termination Processing During Generation of a Fire Alarm or During
Occurrence of a Serious Error in a Projector
When a fire alarm is generated or a serious error occurs in a projector, this system can detect the alarm or
error and execute the set processing. The contents of processing can be set separately.
t
To detect a fire alarm, it is necessary to connect the server and a fire alarm system and perform proper
setting. For more details, refer to “Associating a GPIO channel (only an input pin) with an Emergency
signal (Fire Alarm)” in Section 5-13-4.
1. Tap “Configuration” tab.
2. Tap
[Status]
→
[Emergencies]
.
An Emergencies screen is displayed.
3. In the Emergency Signal pane, select the trigger during processing execution.
Select “Fire Alarm” for processing during generation of a fire alarm. Select “Projector Stop” for
processing during occurrence of an error in a projector.
4. Select the processing performed when the trigger is received. (Multiple items can be selected.)
.
Stop Current Show: Stops the current show.
.
Disable Playback: Stops the current show and disables the playback until emergency is canceled.
.
Douse Lamp:
Closes the douser of a projector.
.
Lamp OFF:
Turns off the lamp.
.
Audio Muting:
Reduces the sound.
.
System Shutdown: Shuts down the system.
t
Only Stop Current Show and Lamp OFF can be selected when Projector Stop is selected in the Emer-
gency Signal pane.
Screen example
[Status] [Emergencies]
Configuration tab
Emergency Signal pane
Emergency Response pane
[Apply]