— 22 —
KV-32XBR400/36XBR400/36XBR400H/38DRC1/38DRC1C
CXA2150D-2
1.
HPOS (H-POSITION)
2.
HSIZ (H-SIZE)
5.
PIN (PIN AMP)
6.
UCP (UP COR PIN COR)
7.
LCP (LOW CO PIN COR)
13. PPHA(PIN PHASE)
14. VANG (AFC-ANGLE)
15. LANG (L-ANGLE)
16. VBOW (AFC-BOW)
17. LBOW (L-BOW)
3-9-2. 1080i HD mode adjustment
1. Input a 1080i HD cross-hatch signal and an HD monoscope
signal that contains overscan markers.
2. Adjust raster position per section 3-8 only if this procedure
was not performed for full mode.
3. Adjust geometry similar to Full DRC mode. Vertical size is
11.8 sq. and Horizontal size is 15.8 sq if monoscope signal is
available. Otherwise use Vertical size as 91.5% scan,
Horizontal size as 90% scan.
4. Use the following register to adjust the horizontal parameter:
A2150-D2
01
HPOS
If necessary, touch up geometry using the data register listed
above for Full mode.
5. Write data into memory.
3-9-3. Vertical Compressed Mode Check and
Confirmation
1. Input a monoscope and a cross-hatch signal.
2. Check vertical compressed mode.
Summary of Contents for KV-32XBR400
Page 53: ...KV 32XBR400 36XBR400 36XBR400H 38DRC1 38DRC1C 53 NOTES ...
Page 54: ...KV 32XBR400 36XBR400 36XBR400H 38DRC1 38DRC1C 54 NOTES ...
Page 75: ... 75 KV 32XBR400 36XBR400 36XBR400H 38DRC1 38DRC1C NOTES 6556 03N 43N 03S 43S 13N 53N NOTES ...
Page 80: ... 80 KV 32XBR400 36XBR400 36XBR400H 38DRC1 38DRC1C 6556 03N 43N 03S 43S 13N 53N NOTES NOTES ...
Page 119: ...KV 32XBR400 36XBR400 36XBR400H 38DRC1 38DRC1C 119 NOTES ...
Page 120: ...KV 32XBR400 36XBR400 36XBR400H 38DRC1 38DRC1C 120 NOTES ...