– 9 –
KF-42WE610/50WE610/60WE610
K
RM-Y913
RM-Y913
RM-Y913
3. Blinking count display of POWER/STANDBY indicator
- One blink is not used for self-diagnosis.
- Example
Diagnosis item
LED blinks
Lamp cover
3 times
Fan
4 times
LED ON : 0.3sec
LED OFF : 0.3sec
- Release of POWER/STANDBY indicator blinking
The POWER/STANDBY indicator blinking display is released by removing the plug from
the power or leaving for 2 minutes.
4. Self-diagnosis screen displays
- In cases of malfunctions where it is not possible to determine the symptom such as when
the power goes off occasionally or when the screen disappears occasionally, there is a
screen display on whether the malfunction occurred or not in the past (and whether the
detection circuit operated or not) in order to allow confirmation.
<Screen Display Method>
- Quickly press the remote command button in the following order from the standby state.
Channel
Vol
Be aware that this differs from
the method of entering the
service mode (Vol +).
Self Diagnosis
SELF DIAGNOSIS
6 : +B OVP
0
1 : LAMP
0
7 : AUDIO
0
3 : LAMP COVER
0
8 : D-OVP
1
4
: FAN
1
101 : WDT
0
Move the joystick
4 : TEMP
0
5 : LAMP DRIVER
0
201 : WDT-ENGINE
0
- Numeral "1" means a fault was detected one time or more.
- Numeral "0" means that no fault was detected.
MAIN
LCD ENGINE
DISPLAY
5
-
POWER
LED OFF
3.0sec