– 19 –
KF-42WE610/50WE610/60WE610
K
RM-Y913
RM-Y913
RM-Y913
SECTION 3
ELECTRICAL ADJUSTMENTS
3-1. ELECTRICAL ADJUSTMENT BY REMOTE
COMMANDER
By using remote commander (RM-Y910K), all circuit adjust-
ments can be made.
NOTE : Test Equipment Required.
1. Pattern Generator (with component outputs)
2. Oscilloscope
3. Digital multimeter
3-1-1. Method of Setting the Service Adjustment
Mode
1. Standby mode. (Power off)
2. DISPLAY
t
5
t
VOL (+)
t
TV POWER
on the remote commander.
(Press each button within a second.)
The following service screen will appear.
Category Name
Item Name
Input Signal
Mode
Item No.
3D-COMB
0
0
SERVICE
NRMD
TV
WSL: xxx
F/A FLAG: xxxxxxxx
CBA FLAG: xxxxxxxx
Data
Category Name
Item Name
Item No.
L001OUT
0
0
G
OCKPN
TEMP 42DEG
LCD PJ ENGINE VER.0.026
9/11
EE2F
Data
<LCD PROJECTOR ENGINE>
3-1-2. Service Mode Adjustment
1. The SCREEN displays the item being adjusted.
2. Press “
1
” or “
4
” on the remote commander to select the
adjustment item.
3. Press “
3
” or “
6
” on the remote commander to change the data.
4. Press “
2
” or “
5
” on the remote commander to select the category.
Every time you press “
2
” (Category up), Service mode
changes in the order as shown below.
VERSION0
CCPS-7
MID4
CCPM-1
CCPS-8
MID5
CCPM-2
CCPS-10
CCPM-3
DCP-INT
AK4524
DLBY
CCPM-4
DCP-OSD
MID1
CCPM-5
D9671TPN
CCPS-5
MID2
CCPM-6
D9671TG1
CCPS-6
MID3
CCPM-7
D9671CUR
D9671TG2
D9671-1
CCD
D9671PIC
DCP-ADJ2
DCP-USER
DCP-AVP
USR-NR
CXA2171
DCP-BLK
DCP-ADJ1
AP
CCPM-8
CCPM-9
CCPM-10
CH-SET
CCPS-1
CCPS-2
CCPS-3
CCPS-4
SNSS
DRCVR
MID6
MID7
MID8
MID9
SNNR
D9671CSC
A7001R
OSD-E
A7001G
A7001B
SH SET
H POS SHI
TEMP
OPTION-E
OPTION-E
FAN-CTL
GB RGB
ID
5. If you want to recover the latest values press “
-
” then
“
[ENTER]
” to read the memory.
6. Press “
[MUTING]
” then “
[ENTER]
” to write into memory.
7. Turn power off.
Note: Press “
8
” then “
[ENTER]
” on the remote commander to
set the shipping conditions or turn set off and on to exit.
3-1-3. Memory Write Confirmation Method
1. After adjustment, turn power off with the remote commander.
2. Turn power on and set to service mode.
3. Call the adjusted items again and confirm they were adjusted.