32
KDL-52V4100/52W4100
KDL-52V4100/52W4100
KDL-52V4100 ONLY
SHEET CORE C (2-688-011-01)
QTY=11
LCD TAPE (2-688-062-01)
QTY=6
SLIDE CLAMP (2-650-770-01)
QTY=1 (UPPER VESA
SUPPORT)
SLIDE CLAMP (2-650-770-11)
QTY=12
CHO-FAB TAPE (2-888-494-01)
QTY=1
HIMELON TAPE (2-661-260-01)
QTY=1
LEGEND
LVDS Cable Routing/Dress
(CRITICAL FOR EMI)
Apply 3x5mm Screw
to secure LVDS Cable to panel and
BU Board bracket.
MAKE SURE clip is centered between
Guides on panel BEFORE installing screw.
CAUTION:
Securing grounding clip with 3x5mm
Screw is CRITICAL FOR EMI
Route LVDS Cable in Slide Clamp.
Clamp is CRITICAL to Prevent LVDS from
Touching high-voltage area on D5 Board.
11
1
8
9
10
2
1
3
Apply 3x8mm Screw
to secure LVDS Cable to panel and
BU Board bracket.
MAKE SURE clip is CENTERED
Between
Guides on Main Bracket BEFORE
installing
Screw.
CAUTION:
Securing grounding clip with 3x5mm
Screw is CRITICAL FOR EMI
See next page for details on
proper installation for cho-fab and
Himelon tapes.
52V has x3 RED UL