HT-XT100
8
2-4. AMP BLOCK
9
two screws
(3
u
8 B2)
1
connector
(XP7)
2
connector
(XP5)
– Rear bottom view –
3
connector
(XP6)
4
FFC 16P/MAIN-FRONT (FFC2)
(XP15)
6
FFC 16P/MAIN-BT
(FFC1)
(XP17)
7
Remove wires
from the hook.
colored line
Insert straight into the interior.
flexible flat
cable
connector
OK
colored line
Insert at a slant.
flexible flat
cable
connector
NG
How to install the flexible flat cable
When installing the flexible flat cable,
ensure that the colored line is parallel
to the connector after insertion.
Insert only part way.
Insert straight into
the interior.
connector
Insert at a slant.
connector
connector
connector
connector
connector
OK
NG
NG
How to install the connector
Insert the connector straight into the interior.
There is a possibility that using this unit without
the connector correctly installed will damage it.
5
connector
(XP4)
:LUHVHWWLQJ
hook
MAIN board
POWER board
8
two screws
(3.5
u
12 B)
0
Remove the AMP block
in the direction of the arrow.
qa
AMP block
The lower side is
the terminal side.
hook