Adjustment Procedure
1.
Open the SERVICE menu, and adjust the item so that the specification is satisfied.
MENU: SERVICE
PAGE: OHB_ADJ1
ITEM: GAIN_CONT [R], [G], [B]
Specification: A = 700 mV
A
R
G
B
100%
A
A
2.
Execute file storing.
MENU: SERVICE
PAGE: OHB_ADJ1
ITEM: STORE FILE
3.
Open the SERVICE menu, and adjust the item so that the specification is satisfied.
MENU: SERVICE
PAGE: WHITE SHADING
ITEM: WHITE [R], [G], [B]
Specification: A = 700 mV
A
R
G
B
100%
A
A
4.
Execute file storing.
MENU: SERVICE
PAGE: WHITE SHADING
ITEM: STORE FILE
5.
Set the value to the value adjusted in steps 1 and 3, and execute file storing for each format.
3-3-4.
V-SUB Adjustment
Preparation
• Setting for MSU-1000
MASTER GAIN → 0
DETAIL OFF button → OFF (lit)
AUTO KNEE button → OFF (lit)
MATRIX OFF button → OFF (lit)
GAMMA OFF button → OFF (lit)
ON button (shutter control block) → OFF (dark)
• Filter position
ND filter → 1 (CLEAR)
• Shoot the grayscale chart so that the chart frame is aligned with the under scanned monitor frame.
• Lens iris: Released
HSC300RF/HSC100RF/HSC300R/HSC100R
3-11