Object: Grayscale chart
Preparation
• Setting for MSU-1000
DETAIL OFF button → ON (dark)
KNEE OFF button → OFF (lit)
MATRIX OFF button → OFF (lit)
• Shoot the grayscale chart so that the chart frame is aligned with the under scanned monitor frame.
• Lens iris: A = 600 ±20 mV (F4 to F5.6)
If the lens aperture is greater than F5.6, adjust the light amount with the shutter.
A
Adjustment Procedure
1.
Operate the menu of MSU-1000.
1) PAINT button → ON (lit)
2) Touch panel operation: (Page 1) → [Flare]
2.
Adjust the levels B to desired level for R, G and B respectively.
Or adjust the levels of other channels to the lowest level B of a channel.
B
3-4-9.
Gamma Correction Adjustment
Equipment: Waveform monitor (R, G, B)
Test Point: SDI connector
Object: Grayscale chart
Preparation
• Setting for MSU-1000
KNEE OFF button → OFF (lit)
GAMMA OFF button → ON (dark)
• Shoot the grayscale chart so that the chart frame is aligned with the under scanned monitor frame.
HSC300RF/HSC100RF/HSC300R/HSC100R