• Lens iris: A = 700 ±20 mV
A
Adjustment Procedure
1.
Operate the control panel of MSU-1000, and perform the automatic white balance adjustment.
WHITE button → ON (lit)
2.
Operate the menu of MSU-1000.
1) PAINT button → ON (lit)
2) Touch panel operation: (Page 2) → [Gamma]
3.
Adjust the levels B to desired level for R, G and B respectively.
To adjust all levels for R, G and B simultaneously, adjust them using Master.
B
3-4-10. Knee Point/Knee Slope Adjustment
Equipment: Waveform monitor (R, G, B)
Test Point: SDI connector
Preparation
• Setting for MSU-1000
MASTER GAIN → 6
TEST 1 button → ON (lit)
KNEE OFF button → ON (dark)
Adjustment Procedure
1.
Operate the menu of MSU-1000.
1) PAINT button → ON (lit)
2) Touch panel operation: (Page 1) → [Knee] → [Knee Slope]
2.
Set the Master adjustment to +99.
3.
Operate the menu of MSU-1000.
Touch panel operation: (Page 1) → [Knee] → [Knee Point]
HSC300RF/HSC100RF/HSC300R/HSC100R
3-23