Setting the Camera Outputs
53
Chap
ter
3
Ba
s
ic
Ad
jus
tme
nt
s
an
d Set
tings
You can select the types of video signals to be
output to the HD SDI MON1, HD SDI MON2,
TEST OUT, and REMOTE connectors.
Use the <MONITOR OUTPUT> page of the
Camera >USER (OPERATION) menu.
COLOR
When you select COLOR, all R, G, and B
channels will be output.
Single-channel output of R, G, or B is also
possible.
MON
You can select the signals to be monitored with
video monitors connected to the HD SDI MON1
and HD SDI MON2 connectors.
TEST
You can select the signals to be output to a video
monitor or waveform monitor connected via the
TEST OUT connector.
RM VIDEO
You can select the video signals to be output to
equipment connected via the REMOTE
connector.
Using the <PB/MON LUT> page of the Camera
>USER (OPERATION) menu, you can select the
gamma setting of the monitor picture and the
playback picture monitor mode.
Setting the Camera
Outputs
Selecting Video Output Signals
for the Connectors
Setting
Signal
MON
Regardless of the VF settings,
characters or markers can be
added independently to the
video output signals (default).
VF
Video signals that are output
to the VF connector (camera
images with character data for
the setting menus, status
displays and so on).
<MONITOR OUTPUT> page
Setting
Signal
VBS
VBS signals (default)
HD-Y
HD-Y signals
FRAME
One pulse per frame
Setting
Signal
VBS
The VBS signals are output. (Default)
HD-Y
The HD-Y signals are output.
Setting the Monitor Picture
Example 1: SHUTTER OFF
1 frame
CCD
exposure
Exposure
Exposure
Frame
pulse
Example 2: SHUTTER ON, shutter angle 180º
CCD
exposure
Exposure
Exposure
Frame
pulse
1 frame
Summary of Contents for HKSR-9003