![Sony HKDV-900 Maintenance Manual Download Page 19](http://html.mh-extra.com/html/sony/hkdv-900/hkdv-900_maintenance-manual_400650019.webp)
2-7 (E)
HKDV-900
9. RS-422A test
Connect the connector tool(s) to the RS-422A connectors at the rear. (Refer to Section 2-2-1.)
Set the test item number to “
09
” using the
[+]
/
[_]
button, and then press the “STORE” button to activate
a test.
Outputs data from “0h” to “ffh” to the RS-422A connector and test that the same data can be received.
n
The states of the test result display that is displayed on the 7SEG LEDs and the LED inside the CON-
TROL SELECT button will change depending on the number of connector tools to be connected.
The states of both LEDs are as follows:
When using the four tools:
Test result
7SEG LED display
LED inside the CONTROL SELECT button
OK
“
PA
”
All light off.
NG
“
Er
”
LED of an abnormal port :
Blinks.
LED of a normal port :
Lights off.
When using the three tools or less:
Test result
7SEG LED display
LED inside the CONTROL SELECT button
OK
“
Er
”
LED of a port to which the tool is connected :
Lights off.
LED of a port to which the tool is not connected :
Blinks.
NG
“
Er
”
LED of a port to which the tool is connected :
Blinks.
LED of a port to which the tool is not connected :
Blinks.
n
If “
Er
” is displayed, see Section 2-3-11, “Troubleshooting for RS-422A Test Error” to clarify the cause.
To quit the test, and press the “CANCEL” button. The 7SEG LEDs display returns to the test item
number.
n
To quit the self diagnostic mode, set the switch S100-8 (J-3) on the CP-364 board back to OFF.
2-2. Self Diagnostic Mode
Summary of Contents for HKDV-900
Page 12: ......
Page 50: ......
Page 54: ......
Page 72: ......
Page 88: ...Printed in Japan Sony Corporation 2004 9 16 B P Company 2000 HKDV 900 SY J E 9 967 923 03 ...