![Sony HDC2400 Operation Manual Download Page 71](http://html.mh-extra.com/html/sony/hdc2400/hdc2400_operation-manual_417994071.webp)
71
Error Messages
If a problem occurs during operation, a warning message is
displayed.
Note
To display a message, set the DISPLAY switch to DISPLAY or
MENU.
Cable (for example)
Max. distance
Min. distance
Fujikura
8.5-mm dia.
700 m (2297 ft)
50 m (164 ft)
Fujikura
14.5-mm dia.
1400 m (4593 ft)
100 m (328 ft)
Belden 9232
13.2-mm dia
1000 m (3281 ft)
75 m (246 ft)
Message
Meaning
TEMP WARNING
The internal temperature is
abnormally high.
FAN STOP
The built-in fan is not rotating
properly.
SET CORRECT SYSTEM DATE The time/date of the internal
clock have not been set.
OHB BLOCK NG!
A problem is detected in the
optical block.
MSU RPN BUSY
RPN compensation was
attempted using the camera
menu while being operated from
an external device.
Consult Sony service personnel.
VF RPN BUSY
RPN compensation was
attempted from an external
device while being operated
using the camera menu.
Consult Sony service personnel.
NO USB FLASH DRIVE
A USB drive operation was
attempted with no USB drive
connected.
USB FLASH DRIVE ERROR
An error occurred during access
to a USB drive.
FORMAT ERROR!
A USB drive operation was
attempted with an unformatted
USB drive.
WRITE PROTECTED
File writing was attempted with a
write-protected USB drive.
FILE ERROR
An error occurred while reading
a file from a USB drive.
OTHER MODEL’S FILE
You attempted to read a file of
other models having no
compatibility.
FILE NOT FOUND
The file you attempted to read
does not exist in the USB drive.