![Sony HDC2400 Operation Manual Download Page 64](http://html.mh-extra.com/html/sony/hdc2400/hdc2400_operation-manual_417994064.webp)
64
<LENS2>
M07
REMOTE CONTROL
OFF
, ON, (OFF)
Lens remote control from MSU/RCP on/off setting.
Same function as the Active button on the Zoom/
Focus Control screen of the MSU/RCP.
(OFF): When lens is not supported
CONTROL
MODE
ZOOM&FOCUS
, FOCUS,
FOLLOW FOCUS
ZOOM & FOCUS:
Control ZOOM and FOCUS from
an MSU/RCP (control by lens demand is not
supported)
FOCUS:
Control FOCUS from an MSU/RCP. ZOOM
is controlled by lens demand.
FOLLOW FOCUS:
FOCUS is controlled by lens
demand, but can be adjusted (offset fine
adjustment) from an MSU/RCP. ZOOM is
controlled by lens demand.
Note
Settings other than FOLLOW FOCUS cannot be
modified when the offset is not 0 and REMOTE
CONTROL is OFF. To change settings, set
REMOTE CONTROL to ON.
FOLLOW FOCUS
OFFSET ADJUST
SENS
1, 2,
3
, 4, 5
Sets the sensitivity of superimposing the offset of
the MSU.
OFFSET
CANCEL GAIN
1, 2,
3
, 4, 5
Sets the sensitivity of canceling the offset on the
demand side.
<MIC GAIN>
M08
MIC1
20, 30, 40, 50,
60
dB
Can be modified only in standalone operation.
MIC2
20, 30, 40, 50,
60
dB
<CALL/TALLY>
M09
CCU CALL
OFF,
ON
Selects whether TALLY lights for CALL signal.
CAM CALL
OFF
, ON
UP TALLY
BRIGHTNESS
TALLY
0 to 100,
50
NUMBER
0 to 100,
50
NUMBER DISPLAY
AUTO
, OFF, ON
CAMERA NUMBER
---
, 1 to 96
CCU LINK
OFF
, ON
ON sets CAMERA NUMBER to the same number
as the CCU number.
TALLY GUARD
Selects whether to prevent changes while TALLY is
lit.
EXTENDER
OFF
, ON
FILTER DISC
OFF
, ON
<OUTPUT FORMAT>
(HDC2500)
M10 (U12)
CURRENT
1080: 24PsF, 59.94i, 29.97PsF,
23.98PsF, 59.94P, 50i, 25PsF,
50P, 59.94i (2×), 50i (2×)
720: 59.94P, 50P, 59.94P (2×),
50P (2×)
Displays the current format.
<OUTPUT FORMAT>
(HDC2400/2570/2550)
M10 (U12)
CURRENT
1080: 59.94i, 50i
720: 59.94P, 50P
Displays the current format.
MAINTENANCE
Page title
PageNo.
Item
Settings
Description