56
HCD-HPX9
CD SECTION
Note:
1.
CD Block is basically designed to operate without adjustment. Therefore,
check each item in order given.
2.
Use YEDS-18 (3-702-101-01) unless otherwise indicated.
3.
Use an oscilloscope with more than 10M
Ω
impedance.
4.
Clean the object lens by an applicator with neutral detergent when the
signal level is low than specified value with the following checks.
S-CURVE CHECK
Procedure :
1. Connect an oscilloscope to TP (FE) and TP (VC) on the CD
board.
2. Press the
I/
1
button to turn the power ON.
3. Load a disc (YEDS-18) and actuate the focus search. (In
consequence of open and close the disc tray, actuate the focus
search)
4. Confirm that the oscilloscope waveform (S-curve) is
symmetrical between A and B. And confirm peak to peak level
within 2.0
±
0.5 Vp-p.
Note:
•
Try to measure several times to make sure than the ratio
of A : B or B : A is more than 10 : 7.
•
Take sweep time as long as possible and light up the
brightness to obtain best waveform.
Connecting Location: CD board
Procedure :
1. Connect an oscilloscope to TP (RFACO) and TP (VC) on the
2. Press the
I/
1
button to turn the power ON.
3. Load a disc (YEDS-18) and playback.
4. Confirm that oscilloscope waveform is clear and check if RFAC
signal level is correct or not.
Note:
Clear RFAC signal waveform means that the shape “
◊
” can be
clearly distinguished at the center of the waveform.
Connecting Location: CD board
CD board
Oscilloscope
TP(FE)
TP(VC)
symmetry
S-curve waveform
within 2.0
±
0.5 Vp-p
A
B
RF signal waveform
VOLT/DIV : 200mV
TIME/DIV : 500ns
level : 0.7
±
0.3 Vp-p
– CD BOARD (Conductor Side) –
TP
(VC)
TP
(FE)
TP
(RFACO)
IC101
www. xiaoyu163. com
QQ 376315150
9
9
2
8
9
4
2
9
8
TEL 13942296513
9
9
2
8
9
4
2
9
8
0
5
1
5
1
3
6
7
3
Q
Q
TEL 13942296513 QQ 376315150 892498299
TEL 13942296513 QQ 376315150 892498299