1-17 (E)
HDVF-C30W
2. Diagnostics of PR-267 Board
Equipment required
.
Camera
.
Oscilloscope
(1) Diagnostics of B side of the PR-267 board
Fixture
Connecting cable
Preparations
1.
Preparation of diagnostics has already been completed
using the EX-909 board.
2.
Set the switch S2-4 on the PR-267 board to OFF.
3.
Remove the EX-909 board.
m
.
Do not disconnect the connecting cable from the
connector (CN1) on the PR-267 board.
.
Do not disconnect the harness from the connector
(CN2) on the RE-208 board.
Diagnostics points
Check the following points with an oscilloscope and
confirm that the waveforms, signals and voltages are
normal.
n
The alphanumeric in parentheses ( ) of Ref.No. indicates
the addresses on the board.
(1) Pin-6/IC7 (B-1)
(2) Pin-6/IC5 (B-1)
1.9 V
1.02 V
Y VIDEO
PB VIDEO
1.5 V
0.9 V
(3) Pin-6/IC6 (B-1)
(4) Pin-4/IC17 (C-2)
.
Controlling AD start signal: 1 pulse/1 H
(5) Voltage
.
R95 (A-1) :
DC 1.5 V
.
Pin-14/IC22 (B-1) : DC 0.5 V
.
Emitter/Q17 (B-1) : DC 2.0 V
PR VIDEO
1.5 V
0.9 V
Q17
IC6
IC5
IC7
IC17
IC22
R95
PR-267 (B side)