SELP1650 (E 3.5-5.6/PZ 16-50 OSS) (E PZ 16-50mm F3.5-5.6 OSS)
4-2
1.
Setting of Equipments
Set the equipments and the checking lens as shown below.
4-1-3. Preparations for Equipments
A flange back adjustment jig and a flange back adjustment chart are necessary for the Flange Back (S) adjustment.
Enlarge the flange back adjustment chart to the specified size and print it fully on the paper.
Size specification: White width 10 mm, black width 10 mm
10mm
10mm
10mm
FB Adjustment chart
The following settings of the printer allows printing that nearly meets the specification.
• Page enlargement/reduction: None
• Magnification: 200%
However, fine-adjust the rate of magnification before printing the chart because the magnification error varies with printer types.
4-2-1. Procedure of Installing the E-Mount Lens Adjustment
Fig.4-2-1
4-2. INSTALLING PROCEDURE
1. Download the lens adjustment program (E-Mount Lens Adjustment.zip) from the ESI homepage.
2. Double click the setup.exe file.
3. The installer screen appears, then click the [Next] button.
Fig.4-2-2
NOTE:
Make sure to perform the installation only by the management.
Do not change the folder to be installed in.
TELE end
Within 10 mm
Flange back
adjustment jig
(J-6082-563-A)
FB Adjustment chart
or
Siemens star chart
(J-6080-875-A)
AC adaptor
(AC-PW20)
(1-487-963-12:EXCEPT US, CND)
(1-487-963-22:US, CND)
Flange back
adjustment jig
Tripod
(optional)
AC
To tripod screw
Fig.4-1-2
Personal computer
(The SeusEX must be installed in the PC.)
OS:
Windows XP Home, Professional SP2 or later / Vista / 7
RAM:
256 MB or more recommended (Windows XP / 7)
1 GB or more recommended (Windows Vista)
USB port:
USB 2.0 recommended (also compatible with 1.1)
Two connectors are required.
Run time:
.NET Framework 2.0
(.NET Framework 2.0 is installed at lens adjustment
program installation, if it is not installed.)
USB cable
(1-829-868-41)
HASP key
To USB connector
Checking
lens
Camera
(NEX-3/5)
To USB connector
Checking lens