– 8 –
DSR-25
SELF-DIAGNOSIS FUNCTION
1.
Self-diagnosis Function
When problems occur while the unit is operating, the self-diagno-
sis function starts working, and displays on the LCD monitor what
to do. This function consists of two display; self-diagnosis display
and service mode display.
Details of the self-diagnosis functions are provided in the Instruc-
tion manual.
Note: The “self-diagnosis display” data will be backed up by the coin-type lithium battery (VD-032 board BT701). When this
coin-type lithium battery is disconnected, the “self-diagnosis display” data will be lost by initialization.
2.
Self-diagnosis Display
When problems occur while the unit is operating, the time code of
the LCD monitor shows a 4-digit display consisting of an alpha-
bet and numbers, which blinks at 3.2 Hz. This 5-character display
indicates the “repaired by:”, “block” in which the problem oc-
curred, and “detailed code” of the problem.
3.
Service Mode Display
The service mode display shows up to six self-diagnosis codes shown in the past.
3-1.
Display Method
Set the “DISPLAY SELECT” switch to “DATA”, turn on the power by the “POWER” switch while pressing the “STOP” key, and continue
pressing the “STOP” key for 5 seconds continuously. The service mode will be displayed, and the time code will show the backup No. and
the 5-character self-diagnosis codes.
3-2.
Switching of Backup No.
By pressing the “
F
” or “
f
” key, past self-diagnosis codes will be shown in order. The backup No. in the [] indicates the order in which the
problem occurred. (If the number of problems which occurred is less than 6, only the number of problems which occurred will be shown.)
[1] : Occurred first time
[4] : Occurred fourth time
[2] : Occurred second time
[5] : Occurred fifth time
[3] : Occurred third time
[6] : Occurred the last time
3-3.
End of Display
Turning OFF the power supply will end the service mode display.
Order of previous errors
Backup No.
Self-diagnosis Codes
C : 3 1 : 1 1
[3]
Lights up
LCD monitor
[3] C : 3 1 : 1 1
1 1
3 1
C
Repaired by:
Refer to page 9.
Self-diagnosis Code Table.
Indicates the appropriate
step to be taken.
E.g.
31 ....Reload the tape.
32 ....Turn on power again.
Block
Detailed Code
Blinks at 3.2Hz
C : Corrected by customer
H : Corrected by dealer
E : Corrected by service
engineer
LCD monitor
C : 3 1 : 1 1
Summary of Contents for DVCAM DSR-25
Page 93: ...DSR 25 2 1 4 97 4 98 RP 234 ...
Page 99: ...DSR 25 4 109 4 110 CM 59 49 48 33 32 17 16 1 2 22 ...
Page 106: ...DSR 25 4 123 4 124 JK 216 JK 216 VIDEO AUDIO IN OUT ...
Page 115: ...4 138 DSR 25 JC 21 BOARD 5 5 6 MHz IC7007 7 REC PB 2 0 Vp p ra ...
Page 122: ...4 145 DSR 25 PD 170 BOARD 2 2 qa IC901 ej REC PB 2 8 Vp p H ...
Page 236: ... 316 Sony EMCS Co 9 929 942 11 2003E0500 1 2003 5 Published by DI Customer Center DSR 25 ...