5-50
DSR-25
9-2. Input of Serial No.
Write the serial No. to the EEPROM (nonvolatile memory).
In writing the serial No., a decimal number should be converted
into a hexadecimal number.
Page
C
Address
32, 33
1) Select page: 0, address: 01, and set data: 01.
2) Read the serial No. from the model name label, and it is as-
sumed to be D
1
.
Example: If serial No. is “77881”,
D
1
= 77881
3) From Table 5-3-2, obtain D
2
that correspond to D
1
.
Example: If D
1
= 77881,
D
2
= D
1
– 65536 = 12345
D
1
(decimal)
D
2
(decimal)
00001 to 65535
D
1
65536 to 131071
D
1
– 65536
131072 to196607
D
1
– 131072
Table 5-3-2
4) From Table 5-3-3, obtain the maximum decimal number less
than D
2
, and it is assumed to be D
3
.
Example: If D
2
= 12345.
D
3
= 12288
5) From Table 5-3-3, obtain a hexadecimal number that corre-
sponds to D
3
, and it is assumed to be H
3
.
Example: If D
3
= 12288,
H
3
= 3000
6) Caluculate D
4
using following equations (decimal
caluculation). (0 D
4
225)
D
4
= D
2
– D
3
Example: If D
2
= 12345 and D
3
= 12288,
D
4
= 12345 – 12288 = 57
7) Convert D
4
into a hexadecimal number to obtain H
4
. (See Table
5-2-2 “Hexadecimal - decimal conversion table” in 5-2. Ser-
vice Mode)
Example: If D
4
= 57,
H
4
= 39
8) Enter higher two digits of H
3
to address: 32 on page: C.
Example: If H
3
= 3000,
select page: C, address: 32, and set data: 30, then press the
PAUSE button.
9) Enter H
4
to address: 33 on page: C.
Example: If H
4
= 39,
select page: C, address: 33, and set data: 39, then press the
PAUSE button.
10) Select page: 0, address: 01, and set data: 00.
9.
Node Unique ID No. Input
Note 1:
Perform “9-2. Input of Serial No.” if the data on page C
has been cleared and the node unique ID No. is not found.
9-1. Input of Company ID etc.
Write the company ID to the EEPROM (nonvolatile memory).
Page
C
Address
2C, 2D, 2E, 2F, 30, 31
Input method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 0, and enter the following data.
Note 2:
Each time the data is set, press the PAUSE button on the
adjusting remote commander.
Address
Data
2C
08
2D
00
2E
46
2F
01
30
02
31
5E
32
Refer to
33
“Input of Serial No.”
3) Select page: 0, address: 01, and set data: 00.
Summary of Contents for DVCAM DSR-25
Page 93: ...DSR 25 2 1 4 97 4 98 RP 234 ...
Page 99: ...DSR 25 4 109 4 110 CM 59 49 48 33 32 17 16 1 2 22 ...
Page 106: ...DSR 25 4 123 4 124 JK 216 JK 216 VIDEO AUDIO IN OUT ...
Page 115: ...4 138 DSR 25 JC 21 BOARD 5 5 6 MHz IC7007 7 REC PB 2 0 Vp p ra ...
Page 122: ...4 145 DSR 25 PD 170 BOARD 2 2 qa IC901 ej REC PB 2 8 Vp p H ...
Page 236: ... 316 Sony EMCS Co 9 929 942 11 2003E0500 1 2003 5 Published by DI Customer Center DSR 25 ...