5-63
3-3.
SYSTEM CONTROL SYSTEM ADJUSTMENT
1.
Initializing the C, D, E Page Data
Note 1:
If “Initializing the C, D, E Page Data” is performed, all
data of the C page, D page and E page will be initialized.
Note 2:
If the C, D, E page data has been initialized, “Modifica-
tion of C, D, E page Data” and all adjustments need to be
performed again.
Mode
E-E
Signal
Arbitrary
Adjustment Page
C
Adjustment Address
00 to 6F
Adjustment Page
D
Adjustment Address
00 to 4F
Adjustment Page
E
Adjustment Address
00 to 3B
2.
Input of C page Initial Data
Input method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 4, address: 02, set data: 01, and press the PAUSE
button of the adjusting remote commander.
3) Select page: 4, address: 02, and confirm that the data change
in the order of “01”
→
“03”
→
“05”
→
“00”.
4) Modify the C page data. (Refer to C page address)
3.
Input of D page Initial Data
Input method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 2, address: 00, set data: 2D, and press the
PAUSE button of the adjusting remote commander.
3) Select page: 2, address: 01, set data: 2D, and press the
PAUSE button of the adjusting remote commander.
4) Select page: 2, address: 02, and confirm that the data is “01”.
5) Modify the D page data. (Refer to D page address)
4.
Input of E page Initial Data
Input method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 5, address: 00, set data: 2D, and press the
PAUSE button of the adjusting remote commander.
3) Select page: 5, address: 01, set data: 2D, and press the
PAUSE button of the adjusting remote commander.
4) Select page: 5, address: 02, and confirm that the data is “01”.
5) Modify the E page data. (Refer to E page address)
5.
Modification of C, D, E, Page Data
If the C, D, E page data has been initialized, change the data of the
“Fixed data-2” address shown in the following tables by manual
input.
Modifying Method:
1) Before changing the data, select page: 0, address: 01, and set
data: 01.
2) New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note :
If copy the data built in the different model, this set may
not operate.
3) When changing the data, press the PAUSE button of the ad-
justing remote commander each time when setting new data
to write the data in the non-volatile memory.
4) Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
5) After completing “Modification of C, D, E Page Data”, select
page: 0, address: 01, and set data: 00. Also perform all adjust-
ments.