1-1
DSC-T500_L3
1. SERVICE NOTE
SY-209 BOARD (SIDE B)
SE1001
YY: YAW Sensor sensitivity
PP: PITCH Sensor sensitivity
YY
PP
SE1002
Note:
The sensor sensitivity of SE1001 and SE1002 of SY-209 board is written only repair parts.
1-1. PRECAUTION ON REPLACING THE SY-209 BOARD
SETTING OF LANGUAGE OF SY-209 BOARD
Two types of SY-209 BOARD, COMPLETE (SERVICE) are exists.
Refer to table below for language settings of two kinds of SY-209 board.
A-1547-808-A SY-209 BOARD, COMPLETE (SERVICE 124) (EXCEPT AEP, UK)
A-1547-809-A SY-209 BOARD, COMPLETE (SERVICE 35) (AEP, UK)
JE
z a
a
a
a
a
a a a a a
PAL
US
z a
a a
a
a
NTSC
CND
z a
a a
a
a
NTSC
z a
a
a
a
a
a a a a a
PAL
z a
a
a
a
a
a a a a a
PAL
a a
z
a
a
a
a a a a a
NTSC
AUS
z a
a a
a
a
PAL
HK
z a
a
a
a
a
a a a a a
PAL
CH
a a
a
a
z
a
a a a a a
PAL
KR
a a
a
a
a
a
z a a a a
NTSC
Thai
a a
a
a
a
a
a a a z a
PAL
AR
a a
z
a
a
a
a a a a a
NTSC
BR
a a
a
z a
a
a a a a a
NTSC
a a a a a a
a z
a a a a a a a a a
PAL
z a a a a a
a
a a a a a a a a a
PAL
z a a a a a
a a
a a a a a a a a a
PAL
UK
z a a a a a
a
a a a a a a a a a
PAL
z
: INITIAL LANGUAGE
VID
E
O
OU
T
Default
AEP
ARE
A
SELECTABLE LANGUAGE
E
Japanese
English
French
German
Spanish
Italian
Portuguese
Simplified
Chinese
Traditional
Chinese
Dutch
Russian
Korean
Persian
Arabic
Thai
Malay
Swedish
Norwegian
Danish
Finnish
Polish
Czech
Hungarian
Turkish
Greek
SY-209
Board
SERVICE
124
SERVICE
35
Language that can be selected about SY-209 board
DESTINATION DATA
When you replace to the repairing board, the written destination data of repairing board also might be changed to original setting.
Refer to Service Manual ADJ, and perform “DESTINATION DATA WRITE”.
USB SERIAL No.
The set is shipped with a unique ID (USB Serial No.) written in it.
This ID has not been written in a new board for service, and therefore it must be entered after the board replacement.
Refer to Service Manual ADJ, and perform “USB SERIAL No. INPUT”.
Angular Velocity Sensor
When you replace to the reparing board, write down the sensitivity displayed on the angular velocity sensor (SE1001 and
SE1002).
Refer to Service Manual ADJ, and perform “Angular velocity sensor sensitivity adj”.