19(E)
5
When “I’m writing to flash memory…done!” appears, set the POWER
switch to OFF, then ON again.
The setting will be registered.
Cleaning operation on the tape streamer
The same cleaning operation as the auto cleaning function can be executed
manually from the display panel.
1
Press the SELECT key of the display panel on the DMS-B9 until
>MAINT MENU appears.
2
Press the SET key.
The display changes to >Mt:EXIT.
3
Press the UP or DOWN key to display >Mt:Cleaning.
4
Press the SET key.
When the command is sent, OK appears.
5
Press the UP or DOWN key until >Mt:EXIT appears.
6
Press the SET key.
Notes
• To use this function, designate the bin number for the cleaning cassette
with the software switch.
• A cleaning cassette must be set in the designated bin.
• Do not execute a cleaning operation with a cassette inserted in the tape
streamer.
For details on cleaning the tape streamer and the timing for cleaning, refer to the
operation manual furnished with the tape streamer.