6-38
DCR-PC350/PC350E
23. Strobe Light Level Adjustment
Adjust the light level when the strobe light flashes.
Subject
Paper which reflection rate is 18%
(50cm from the front of the lens)(Note1)
Measurement Point
Adjustment remote commander
Measuring Instrument
Adjustment Page
F
Adjustment Address
8C to 91
Specified Value
Data of page: 6, address: 0C is “00”.
Note1:
Background paper (J-250-130-A). Perform this adjustment in the
dark room or use the flash adjustment box. (Refer to “1-1-
3.Precaution”.)
Note2:
Any light other than the strobe light should not light up the paper.
Note3:
This adjustment should be carried out upon completion of “HALL
Adjustment”, “Flange Back Adjustment” and “F No. & ND Light
Quantity Standard Data Input”.
Note4:
The data of page: 0, address: 10 must be “00”.
Note5:
Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Switch setting:
1)
POWER ....................................................... CAMERA-TAPE
2)
FLASH ......................................................... Forced flash ( )
(Press FLASH ( ) button and set to the forced flash mode.)
3)
NIGHT SHOT .................................................................. OFF
How to reset the flash error flag
When the flash error self-diagnosis code (E: 91: **) is displayed.
After repair, clear the error flag in the following method.
Order Page Address Data
Procedure
1
7
01
75
Set the data.
2
7
00
01
Set the data, and press PAUSE
button.
3
7
02
Check that the data is “01”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
7
01
7E
Set the data.
3
7
04
01
Set the data.
4
7
00
01
Set the data, and press PAUSE
button.
5
6
65
AE
Set the data.
6
6
C9
10
Set the data.
7
6
01
67
Set the data, and press PAUSE
button.
8
Check the flashing.
9
6
02
Check that the data is “01”. (Note6)
10
6
0C
Check that the data is “00”.
Note6:
The adjustment data will be automatically input to page: F, address:
8C to 91.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
7
01
7E
Set the data.
3
7
04
00
Set the data.
4
7
00
01
Set the data, and press PAUSE
button.
5
6
65
00
Set the data.
6
6
C9
00
Set the data.
7
0
01
00
Set the data.
Summary of Contents for DCR-PC350 - Digital Handycam Camcorder
Page 3: ... 3 DCR PC350 PC350E ENGLISH JAPANESE ENGLISH JAPANESE ...
Page 5: ... 5 DCR PC350 PC350E ENGLISH JAPANESE ENGLISH JAPANESE ...
Page 12: ...1 6 DCR PC350 PC350E SECTION 1 SERVICE NOTE ENGLISH JAPANESE ENGLISH JAPANESE ...
Page 13: ...1 7 DCR PC350 PC350E ENGLISH JAPANESE ENGLISH JAPANESE ...
Page 14: ...1 8 DCR PC350 PC350E ENGLISH JAPANESE ENGLISH JAPANESE ...
Page 15: ...1 9 DCR PC350 PC350E ENGLISH JAPANESE ENGLISH JAPANESE ...
Page 16: ...1 10E DCR PC350 PC350E ENGLISH JAPANESE ENGLISH JAPANESE ...
Page 72: ...5 14 5 REPAIR PARTS LIST 5 REPAIR PARTS LIST DCR PC350 PC350E J MODEL ...
Page 79: ...ENGLISH JAPANESE ENGLISH JAPANESE ...
Page 153: ...ENGLISH JAPANESE ENGLISH JAPANESE ...