17. AF Laser Output Adjustment
Set the AF laser output to an appropriate level.
Subject
Paper which reflection rate is 18%
(50cm from the front of the lens)
(Note1)
Measurement Point
Adjustment remote commander
Measuring Instrument
Adjustment Page
F
Adjustment Address
66 to 6C
Specified Value
Data of address: 66 is “10” to “FF”.
Data of address: 6B is “15” to “20”.
Note1:
Background paper (J-2501-130-A). Perform this adjustment in the
dark room or use a dark box.
Note2:
Any light other than the laser light should not light up the paper.
Note3:
This adjustment should be carried out upon completion of the
following adjustments.
“HALL Adjustment”, “Flange Back Adjustment”
Note4:
The data of page: 0, address: 10 must be “00”.
Note5:
Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Switch setting:
1)
POWER .................................................................. CAMERA
2)
NIGHT SHOT .................................................................. OFF
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
01
AF
Set the data, and press PAUSE
button.
3
Check the laser light is output.
4
6
02
Check that the data is “01”.
(Note6)
5
F
66
Check that the data is “10” to
“FF”.
6
F
6B
Check that the data is “15” to
“20”.
Note6:
The adjustment data will be automatically input to page: F, address:
66 to 6C.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
0
01
00
Set the data.