5-58
DCR-IP45/IP45E/IP55/IP55E
3-4.
VIDEO SYSTEM ADJUSTMENTS
Before perform the video system adjustments, check that the
specified value of “54MHz/66MHz Origin Oscillation Adjustment”
of “CAMERA SYSTEM ADJUSTMENT” is satisfied.
And check that the data of page: 0, address: 10 is “00”. If not, set
data: 00 to this address.
Note:
NTSC model: DCR-IP45/IP55
PAL model: DCR-IP45E/IP55E
Switch setting:
POWER .................................................................. CAMERA
DEMO MODE (Menu setting) ........................................ OFF
1. Chroma BPF fo Adjustment (DI-085 Board)
Set the center frequency of the chroma band-pass filter of IC2401.
Mode
Camera
Subject
All black (Cover the lens with the lens
cap)
Measurement Point
CH1: Chroma signal terminal of S
VIDEO plug of A/V jack (75
Ω
terminated)
CH2: Y signal terminal of S VIDEO
plug of A/V jack (75
Ω
terminated)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
3C
Specified Value
A = Minimum
Note1:
The data of page: 0, address: 10 must be “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
3
00
12
Set the data, and press PAUSE
button.
3
C
3C
Change the data for minimum
amplitude of the burst signal
level (A).
(The data should be “00” to “07”.)
4
C
3C
Press PAUSE button.
5
3
00
00
Set the data, and press PAUSE
button.
6
0
01
00
Set the data.
2. S VIDEO OUT Y Level Adjustment (VC-291 Board)
Mode
Camera
Subject
Arbitrary
Measurement Point
Y signal terminal of S VIDEO plug of
A/V jack (75
Ω
terminated)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
94
Specified Value
A = 714
±
14mV (NTSC)
A = 700
±
14mV (PAL)
Note1:
The data of page: 0, address: 10 must be “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
3
02
FE
Set the data.
3
3
00
07
Set the data, and press PAUSE
button.
4
3
07
Check that bit1 of the data
changes to “1”. (Note2)
5
C
94
Change the data and set the Y
signal level (A) to the specified
value.
6
C
94
Press PAUSE button.
7
3
00
00
Set the data, and press PAUSE
button.
8
3
02
00
Set the data.
9
0
01
00
Set the data.
Note2:
For the bit values, refer to “5-4. SERVICE MODE”, “4-3. 3. Bit
value discrimination”.
Fig. 5-3-5.
Fig. 5-3-6.
CH1
CH2
A
H
H
Center of luminance line
A