– 18 –
14. Auto White Balance Check
Mode
CAMERA
Subject
Clear chart
(Color reproduction adjustment
frame with the zoom lens at
WIDE end)
Measurement Point
Displayed data of Video terminal
of Page: 1
A/V OUT jack
(Note 3)
(75
Ω
terminated)
Measuring Instrument
Adjusting remote Vectorscope
commander
Specified Value
R ratio:
Fig. 5-1-18
3E00 to 4200
(A) and (B)
B ratio:
3E00 to 4200
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 2:
Refer to “Picture Frame Setting” for YH and YL.
Note 3
: The right 4 digits of the page: 1 displayed data of the
adjusting remote commander.
1:XX:XX
Displayed data
Checking method:
Order Page Address Data
Procedure
1
Check that the lens is not
covered with either filter.
2
0
01
01
3
Perform “Data setting during
camera system adjustments”.
(Refer to page 5-14)
4
6
2C
01
5
6
90
00
6
6
91
00
7
6
92
YL
(Note 2)
8
6
93
YH
(Note 2)
9
6
01
79
Press PAUSE button.
10
6
07
Check the data changes to “01”.
11
6
01
00
Press PAUSE button.
INDOOR data check (without ND filter)
12
E
52
Note down the data.
13
E
52
0E
Press PAUSE button.
14
6
01
0F
Press PAUSE button.
15
0
03
04
16
1
Check that the displayed data
(Note 3) satisfied the R ratio
specified value.
17
0
03
05
18
1
Check that the displayed data
(Note 3) satisfied the B ratio
specified value.
INDOOR luminance point check
19
Check that the center of the
white luminance point within
the circle shown
Fig. 5-1-18 (A).
OUTDOOR luminance check
20
Place the C14 filter on the
lens.
21
E
4B
Note down the data.
22
E
4B
20
Press PAUSE button.
23
6
01
3F
Press PAUSE button.
24
Check that the center of the
white luminance point settles
in the circle shown
Fig. 5-1-18 (B).
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
0
03
00
2
6
01
00
Press PAUSE button.
3
6
2C
00
4
6
92
00
5
6
93
00
6
E
4B
Set the data noted down at
step 21, and press PAUSE
button.
7
E
52
Set the data noted down at
step 12, and press PAUSE
button.
8
Release the data setting
performed at step 3 .
(Refer to page 5-14)
9
0
01
00
10
Remove the C14 filter on the
lens.
R-Y
B-Y
4 mm
4 mm
Fig. 5-1-18 (A)
Fig. 5-1-18 (B)
R-Y
B-Y
1.5 mm
1 mm
6 mm
6 mm
Ver. 1.1 2001. 08