DSC-P51/P51M
5-22
11. Auto White Balance 3200K Check 2
RadarW
RadarW
RadarW
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Measurement Point
Displayed data
Video terminal of
of Page: 1
VIDEO OUT jack
(Note 3)
(75
Ω
terminated)
Specified Value
R ratio: 3F60 to 40A0
B ratio: 3F60 to 40A0
R-Y level data: 007E to 0082
B-Y level data: 007E to 0082
Note 1:
Perform this check after “Auto white Balance 3200K
Check 1” without a break.
Note 2:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 3:
The right four digits of the page: 1 displayed data of the
adjusting remote commander.
1:XX:XX
Displayed data
Checking method:
Order Page Address Data
Procedure
1
“Auto White Balance 3200K
Check 1” is completed.
2
6
37
0E
3
6
01
0F
Press PAUSE button.
4
6
02
Check the data changes to
“01”.
5
0
03
04
6
1
Check that the displayed data
(Note 3) satisfied the R ratio
specified value.
7
0
03
05
8
1
Check that the displayed data
(Note 3) satisfied the B ratio
specified value.
9
0
03
2E
10
1
Check that the R-Y level data
(Note 3) satisfied the
specified value.
11
0
03
2F
12
1
Check that the B-Y level data
(Note 3) satisfied the
specified value.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
6
37
00
3
0
03
00
4
7
5D
Set the data that is kept as a
memo in step 4 of “Auto
White Balance 3200K
Standard Data Input”, and
press the PAUSE button.
(Refer to page 5-20)
5
Release the data setting
performed in step 1 of “Auto
White Balance 3200K
Standard Data Input”.
(Refer to page 5-13)