DSC-P51/P51M
5-20
8.
Mixed Color Cancel Adjustment
RadarW
RadarW
RadarW
To perform mixed color cancel adjustment based on data of each
color in color bar.
Mode
CAMERA
Subject
Color bar chart
(Standard picture frame with the
zoom lens at WIDE end)
Adjustment Page
F
Adjustment Address
6E and 6F
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Adjusting method:
Order Page Address Data
Procedure
1
Perform “Data setting during
camera system adjustment”.
(Refer to page 5-13)
2
Perform “Picture Frame
setting”.
(Refer to page 5-14)
3
7
5D
Note down the data.
4
7
5D
81
Press PAUSE button.
5
7
22
Note down the data.
6
7
22
00
Press PAUSE button.
7
6
01
D7
Press PAUSE button.
8
6
01
D5
Press PAUSE button.
(Note 2)
9
6
02
Check the data changes to
“01”.
Note 2:
The adjustment data will be automatically input to page:
F, address: 6E and 6F.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
7
22
Set the data noted down at
step 4, and press PAUSE
buttton.
3
7
5D
Set the data noted down at
step 3, and press PAUSE
button.
4
Release the data setting
performed at step 1.
(Refer to page 5-13)
9.
Auto White Balance 3200K Standard Data Input
Adjust the white balance standard data at 3200K.
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Adjustment Page
F
Adjustment Address
70 to 77, B0, B2, B4
Note 1:
“Auto White Balance 3200K Check 1” and “Auto White
Balance 3200K Check 2” should be performed continu-
ously if “Auto White Balance 3200K Standard Data In-
put” is performed.
Note 2:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 3:
“Auto White Balance 3200K Standard Data Input” is
available only once after the power is turned on. Turn the
power off, then on again if the adjustment is retried.
Adjusting method:
Order Page Address Data
Procedure
1
Perform “Data setting during
camera system adjustment”.
(Refer to page 5-13)
2
Perform “Picture Frame
setting ”. (Refer to page 5-
14)
3
6
B6
03
4
7
5D
Note down the data.
5
7
5D
81
Press PAUSE button.
6
6
37
01
7
6
01
11
Press PAUSE button.
8
6
38
Check the data changes to
“01”.
9
6
01
C1
Press PAUSE button. (Note 4)
10
6
02
Check the data changes to
“01”.
11
6
01
00
Press PAUSE button.
12
6
37
02
13
6
01
0B
Press PAUSE button. (Note 4)
14
6
02
Check the data changes to
“01”.
Note 4:
The adjustment data will be automatically input to page:
F, address: 70 to 77, B0, B2 and B4.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
Perform “Auto white Balance
3200K Check 1”.
RadarW
RadarW
RadarW