DSC-P51/P51M
5-15
1.
HALL Adjustment
RadarW
RadarW
RadarW
RadarW
RadarW
Mode
CAMERA
Subject
Not required
Measurement Point
Displayed data of page: 1
(Note 2)
Measuring Instrument
Adjusting remote commander
Adjustment Page
F
Adjustment Address
58 to 5D, 68
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Adjusting method:
Order Page Address Data
Procedure
1
Perform “Data setting during
camera system adjustment”.
(Refer to page 5-13)
2
6
94
16
3
6
95
86
4
6
01
6D
Press PAUSE button.
(Note 2)
5
6
02
Check the data changes to
“01”.
6
6
01
00
Press PAUSE button.
Note 2:
The adjustment data will be automatically input to page:
F, address: 58 to 5D and 68.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
6
94
00
3
6
95
00
4
0
03
00
5
Release the data setting
performed at step 1.
(Refer to page 5-13)