– 11 –
Aging procedure:
Some operating method will be changed depending on if the fol-
lowing jig for the aging mode exists or not.
• Jig
Parts. No
Description
J-2501-123-A
Remote commander (For aging mode)
With remote commander for aging mode:
1. Turn ON the power of the unit. Open the front cover.
2. Press the
[AGING START]
button of the remote commander
for aging mode.
3. When the disc set mode is set, the
·
and
P
LEDs blink.
4. Rotate the JOG dial. The slits (No. 10, 20, 30, 40, 51) for set-
ting the discs will come forward. Insert the discs into these
slits. Do not set the discs in other slits.
5. Set the use/disuse of the self protection function in errors. Press
the
[REPEAT]
button. When REPEAT is displayed on the fluo-
rescent indicator tube, the self protection function during the
error will become “Use”.
If the REPEAT display is OFF, it means that the function is
not used. (Normally set to “Use” when performing aging.)
6. Press the
·
button.
7. The
·
LED blinks, the aging mode is set, and aging is
started.
8. The aging cycle lasts 3 minutes. When problems occur during
aging, the error number will be displayed on the fluorescent
indicator tube, and the
P
LED will light up.
(Refer to the following table for the details of the errors.)
9. Aging will be repeated as long as no errors occur.
10. After each aging cycle, the number displayed on the Fluores-
cent indicator tube will increase.
11. To end aging, press the
I
/
u
button
Error Display
Error code
Without remote commander for aging mode:
1. Turn ON the power of the unit. Open the front cover.
2. Press the
[PLAY MODE]
,
·
, and
≠
buttons in order.
3. When the disc set mode is set, the
·
and
P
LEDs blink.
The following procedure is the same as in the case “With remote
commander for aging mode”.
Code number
Name
Contents
Err 01
DISC sensor check 1
No disc in the specified slit
Err 02
DISC sensor check 2
Disc in other slits
Err 03
No function
Err 04
Table operation check 2
No table sensor input
Err 05
Loading operation check 1
Load in timeover
Err 06
Loading operation check 2
Load out timeover
Err *1
BU related check 1
Access timeover
Err *2
BU related check 2
High speed search NG
Err *3
BU related check 3
Q data read error
Err *4
BU related check 4
BU operation (From focus search to until signal can be read) timeover
Err *5
BU related check 5
GFS monitor error
Err *6
BU related check 6
Focus cannot be imposed by focus search
The * numbers mean the following according to the state of the unit during aging
2 : From checking to end of TOC read
3 : From end of TOC read to end of last track playback
4 : From end of last track playback to end of first track playback
Disc number
Error code
number of agings
(1
n
2
n
3
n
.....)
DISC
51
26
Err
*