5-46
CCD-TRV107/TRV108/TRV308/TRV408/TRV608
6. Switch check (3)
Page 2
Address 60 to 65
Using method:
1)
Select page: 2, address: 60 to 65.
2)
By discriminating the display data, the pressed key can be discriminated.
*1: Video light model (CCD- TRV107/TRV308/TRV408/TRV608)
7. Record of Use check
Note:
When replacing the drum assembly, initialize the data of address: A2 to A4.
When replacing the video light, initialize the data of address: E0 to E2.
Page 2
Address A2 to AA and E0 to E2
Address
60
(KEY AD0)
(IC503
od
)
61
(KEY AD1)
(IC503
of
)
62
(KEY AD2)
(IC503
og
)
63
(KEY AD3)
(IC503
oh
)
64
(KEY AD4)
(IC503
oj
)
65
(KEY AD5)
(IC503
ok
)
00 to 0C
MENU
(CF-2000)
(S002)
PANEL
REVERSE
(PR-1000)
0D to 24
LIGHT
(FK-2000)
(S002) *1
TITLE
(CF-2000)
(S006)
DISPLAY
(CF-2000)
(S005)
FADER
(CF-2000)
(S004)
25 to 3F
STOP
(FK-2000)
(S005)
PAUSE
(FK-2000)
(S006)
EXPOSURE
(CF-2000)
(S009)
TIME
(CF-2000)
(S023)
40 to 5D
FF
(FK-2000)
(S007)
REW
(FK-2000)
(S008)
VOL+
(CF-2000)
(S0012)
END SEARCH
(CF-2000)
(S010)
5E to 81
PLAY
(FK-2000)
(S009)
VOL–
(CF-2000)
(S0015)
E DUBBING
(CF-2000)
(S013)
82 to AA
DATE
(CF-2000)
(S022)
COUNTER RESET
(CF-2000)
(S017)
BACK LIGHT
(CF-2000)
(S016)
Data
AB to D7
PANEL
CLOSE
(CF-2000)
(S001)
EXEC
(CF-2000)
(S019)
FOCUS
(CF-2000)
(S018)
D8 to FF
No key input
No key input
PANEL OPEN
(CF-2000)
(S001)
No key input
No key input
PANEL
NORMAL
(PR-1000)
Bit
A2
A3
A4
A5
A6
A7
A8
A9
AA
E0
E1
E2
Function
Drum rotation
Hour (H)
counted time
Hour (L)
(BCD code)
Minute
User initial power
Year
on date
Month
(BCD code)
Day
Final condensation
Year
occurrence date
Month
(BCD code)
Day
Video light
Hour (H)
counted time
Hour (L)
(BCD code)
Minute
Remarks
1000th place digit and 100th place digit of counted time (decimal digit)
10th place digit and 1st place digit of counted time (decimal digit)
After setting the clock, set the date of power on next
1000th place digit and 100th place digit of counted time (decimal digit)
10th place digit and 1st place digit of counted time (decimal digit)
Using method:
1)
The record of use data is displayed at page: 2, addresses: A2 to AA and E0 to E2.
Note:
This data will be erased (reset) when the cabinet (R) assembly (VC-272 board CN709 (24P)) is removed.
Initializing method:
1)
Using the adjustment remote commander, select the object address and set data: 00.