Manual RPN Correction Settings
Chapt
er
3
B
as
ic
A
djus
tment
s
and Se
tt
ing
s
Registering pixel coordinates for
correction while displaying a magnified
image
To register the pixel coordinates for which correction will
be performed, press the ASSIGN 1 button to switch to
magnified display, and switch to the registration screen.
An icon that indicates the position of the magnified display
appears at the bottom right.
The following functions will be assigned to the ASSIGN 1
to 4 buttons in this mode.
1
Rotate the MENU SEL/ENTER dial to move the cross
cursor so that the pixel you want to register is centered.
Switch between up, down, left, and right movements
by pressing the MENU SEL/ENTER dial.
2
After moving to the pixel you want to correct, press the
ASSIGN 4 button to register the pixel coordinates.
A confirmation dialog box appears.
3
Select OK, and press the MENU SEL/ENTER dial.
4
When you are finished registering, use the BACK
button or ASSIGN 1 button to return to the <Manual
RPN> settings screen.
• The pixel that appears in the center of the cross cursor
will appear with correction applied in real time while the
cursor is displayed. This occurs only while the cursor is
displayed, and the pixel will not be stored as a correction
pixel unless registration is performed.
• Before performing registration, press the ASSIGN 3
button to switch the cursor display On and Off, and
verify that the pixel you want to register is positioned
properly in the center of the cursor. Similarly, switch the
cursor display On and Off after performing registration
to verify that registration was performed properly.
3-8-2 Deleting Registered RPNs
When Operation is set to Delete in the <Manual RPN>
settings screen, the registration deletion screen appears.
All ASSIGN buttons are disabled in this mode, and
operations can only be performed from the VF menu.
1
Select the Jump button, press the MENU SEL/ENTER
dial, and move the cursor position to the registered
pixel.
Press the MENU SEL/ENTER dial repeatedly until the
cursor is on the target pixel.
2
Select the Delete button, and press the MENU SEL/
ENTER dial.
A confirmation dialog box appears.
3
Select the OK button, and press the MENU SEL/
ENTER dial.
The pixel coordinates are deleted and removed as
targets for correction.
Button
Function
Setting
ASSIGN 1
Mag
Sets whether to magnify the
display.
ASSIGN 2
Mag Pos. Moves the magnified display
position.The rectangular marker
that appears on the screen when
magnified display is Off indicates
the position of the magnified
display.
ASSIGN 3
Cursor
Sets whether to display the cross
cursor used for registration.
ASSIGN 4
-
N/A
Button
Function Setting
ASSIGN 1
Mag
Sets whether to magnify the
display.
ASSIGN 2
Mag Pos. Moves the magnified display
position.
ASSIGN 3
Cursor
Sets whether to display the cross
cursor used for registration.
ASSIGN 4
Add
Executes registration of the
correction pixel coordinates.
Notes