background image

iDC CPU BOARD

BKSI-2440

iDC LINK INTERFACE BOARD

BKSI-2441

IDC SERIAL I/F CONNECTOR BOARD

BKSI-2042

IDC PARALLEL I/F CONNECTOR BOARD

BKSI-2043

IDC S-BUS I/F CONNECTOR BOARD

BKSI-2044

INSTALLATION MANUAL
2nd Edition (Revised 1)
Serial No. 10112 and Higher: BKSI-2440
Serial No. 10026 and Higher: BKSI-2441
Serial No. 10490 and Higher: BKSI-2042
Serial No. 10589 and Higher: BKSI-2043
Serial No. 10730 and Higher: BKSI-2044

Summary of Contents for BKSI-2040 Series

Page 1: ...PARALLEL I F CONNECTOR BOARD BKSI 2043 IDC S BUS I F CONNECTOR BOARD BKSI 2044 INSTALLATION MANUAL 2nd Edition Revised 1 Serial No 10112 and Higher BKSI 2440 Serial No 10026 and Higher BKSI 2441 Serial No 10490 and Higher BKSI 2042 Serial No 10589 and Higher BKSI 2043 Serial No 10730 and Higher BKSI 2044 ...

Page 2: ...rden Um die Gefahr eines elektrischen Schlages Feuergefahr und Verletzungen zu vermeiden sind bei Wartungsarbeiten strikt die Angaben in der Anleitung zu befolgen Andere als die angegeben Wartungsarbeiten dürfen nur von Personen ausgeführt werden die eine spezielle Befähigung dazu besitzen AVERTISSEMENT Ce manual est destiné uniquement aux personnes compétentes en charge de l entretien Afin de réd...

Page 3: ...hock Turn off the power and unplug the appliance from the outlet before installing When disconnecting a connector be careful about the edges on the connector panel Disconnecting a connector with excessive force may cause an injury of your fingers from the edges on the connector panel Hold a harness of a connector firmly and disconnect it softly 1 P ...

Page 4: ......

Page 5: ...and Function of Connectors 1 10 E 1 5 2 Connecting Connector and Cables 1 10 E 1 5 3 Signal Inputs Outputs 1 11 E 1 5 4 Switch Setting 1 11 E 1 6 Information of BKSI 2042 1 12 E 1 6 1 Location and Function of Connectors 1 12 E 1 6 2 Connecting Connector 1 12 E 1 6 3 Signal Inputs Outputs 1 13 E 1 6 4 Switch Setting 1 13 E 1 6 5 Connection of the RS 232C 422A Connectors 1 14 E 1 7 Information of BK...

Page 6: ......

Page 7: ...iDC Link Interface Board BKSI 2040 series BKSI 2042 IDC Serial I F Connector Board BKSI 2043 IDC Parallel I F Connector Board BKSI 2044 IDC S BUS I F Connector Board Related manual The following manual is prepared for this series BKSI 2440 Maintenance Manual Available on request This manual describes the general service information and detailed information with the intention of servicing based on ...

Page 8: ...nformation for BKSI 2440 1 5 Information of BKSI 2441 This section describes the information for BKSI 2441 1 6 Information of BKSI 2042 This section describes the information for BKSI 2042 1 7 Information of BKSI 2043 This section describes the information for BKSI 2043 1 8 Information of BKSI 2044 This section describes the information for BKSI 2044 1 9 Specifications This section describes the s...

Page 9: ...ntroller Each device of the SMS can be controlled when this board is used as a pair with each board BKSI 2042 BKSI 2043 or BKSI 2044 BKSI 2441 iDC LINK INTERFACE BOARD IF 905 BOARD This connector panel carrys out the interface with SMS gateway or the interface between iDC boards BKSI 2042 IDC SERIAL I F CONNECTOR BOARD IO 111 BOARD This connector panel is used for the RS 232C 422A interface Use th...

Page 10: ...ontroller CPU BKSI 2440 BKSI 2441 Device controller CPU BKSI 2440 BKSI 204x Device controller CPU BKSI 2440 BKSI 204x LAN Ethernet SMS gateway IBM PC AT compatible machine with BSS 1 software SIU 80A 80 iDC Controlled devices PC with Application software iDC Concept ...

Page 11: ...ures for the front plug in board and rear connector panel in a System Interface Unit SIU 80A 80 For more details of each procedure refer to the applicable sections and Installation Manual supplied with SIU 80A or SIU 80 1 2 1 Plug in Board Installation Flow for installation Start Slot selection Switch setting on board Plug in board installation BKSI 2440 Compact flash card installation Model label...

Page 12: ...er on Touching the power contact portion or the primary winding circuit on the SIU 80A 80 may cause electric shock Turn off the power and unplug the power cord from the outlet before installing Information for inserting slot A When the board uses for root controller Insert this board into the No 1 slot It is necessary to install the one root controller board in the one Server Management System SMS...

Page 13: ...nstalled in the only one of SIU 80A 80 units BKSI 2042 2043 2044 These connector panels are inserted into any slot No 2 to No 8 in the rear of SIU 80A 80 Use each panel a pair with device controller BKSI 2440 which is inserted in the front slot of SIU 80A 80 Blank panel BVTT 3 x 6 SIU 80A 80 Connector panel Model label SIU 80A 80 BVTT 3 x 6 Procedures 1 Turn the SIU 80A 80 power off and unplug the...

Page 14: ...d as the SMS gateway BKSI 2441 SMS gateway SIU 80A 80 Rear side Rear side 1 2 SMS GW RJ 45 LAN connectors RJ 45 Ethernet switching hub Ethernet cables Straight cable Ethernet cables Straight cable 1 1 2 ADDRESS 3 4 Connection of multiple SIU 80A 80 units installed iDC boards Connection is the same as the one of one SIU 80A 80 n Install the root controller BKSI 2440 to the one SIU 80A 80 of which w...

Page 15: ... multiple iDC boards in the one Server Management System by the only one 2 Connect the SIU 80A 80 units using any cables RCC 5G RCC 10G and RCC 30G as shown in the figure 1 Connected when a dual homing system such as the FT server is used as the SMS gateway n The maximum total length of the cables connecting the SIU 80A 80 units is 30 m maximum data transmission distance The cable shown in the fig...

Page 16: ...4 CN1203 CN1202 CN500 1 ON 2 3 4 S700 A 4 System setting dip switch This switch is used for setting of the system operation The following figure shows the factory settings S700 1 ON Boot monitor OFF Usual factory setting S700 2 ON Factory use only OFF Usual factory setting S700 3 to 4 Unassigned factory settings OFF S500 A 5 S501 A 4 S1202 A 4 CPU reset push switch CPUs on the CPU 356 board are re...

Page 17: ...lash card Displays the operation status for the Compact flash card indicator Lights in green Compact flash card is being connected Blinks in green Compact flash card is in operation Blinks in red Compact flash card is in preparation to be connected released No light Compact flash card is ready to be relased D714 A 1 IF CPU indicator Displays the operation status for the IF CPU For route board Blin...

Page 18: ...ors are used for communications between SMS gateway and root controller BKSI 2440 Connect to the LAN connectors on the SMS gateway 1 5 2 Connecting Connector and Cables When connecting cable to connectors on the connector panel at the time of installing or servicing use the following connector cables or equivalents Connectors on BKSI 2441 Matching connector cables Panel Indication Connector Connec...

Page 19: ... 9 pin female External View Pin No Signal 1 NC 2 LINK OUT 3 LINK IN _ 4 GND 5 FRAME SIGNAL 6 GND 7 LINK OUT _ 8 LINK IN 9 NO REF iDC LINK IN 2 OUT 2 D sub 9 pin female External View Pin No Signal 1 NC 2 LINK IO 3 GND 4 GND 5 FRAME SIGNAL 6 GND 7 LINK IO _ 8 GND 9 NO REF 1 5 4 Switch Setting IF 905 board A side component side Switches S2000 S2001 Link termination select switch S2000 ON factory sett...

Page 20: ...connectors depending upon the internal connection of connectors on the board 2 RS 232C indication slots When the internal connection connector on the board is connected to RS 232C it can be confirmed through this slot 1 6 2 Connecting Connector When connecting cable to connectors on the connector panel at the time of installing or servicing use the following connector or equivalent Connectors on B...

Page 21: ...ME GND FRAME GND 2 RXD I RX TX 3 TXD O TX RX 4 DTR O GND GND 5 GND NC NC 6 DSR I GND GND 7 RTS O RX TX 8 CTS I TX RX 9 NC NC NC COR5 COR6 COR3 COR4 COR1 COR2 COR Slide switch COR1 COR2 COR3 COR4 COR5 COR6 RS 422A signal termination switches The COR1 to COR6 correspond to the RS 232C 422A connectors D sub 9 pin 1 to 6 respectively Switch setting to each connector individually is possible ON 100 Ω t...

Page 22: ... on the connector panel confirm that the RS 232C signal names of this connector Refer to 1 6 3 Signal Inputs Outputs and the signal names of the connector of other equipment CN43 CN53 CN63 CN73 CN83 CN93 For RS 422A M setting Connect these connectors when the respective RS 232C 422A connectors on the connector panel are used as the RS 422A controlling devices Factory setting CN44 CN54 CN64 CN74 CN...

Page 23: ...nnections When any input pin is connected to GND the corresponding signal is turned on Output is provided with open collector circuit 1 7 2 Connecting Connector When connecting cable to connectors on the connector panel at the time of installing or servicing use the following connector or equivalent Connectors on BKSI 2043 Matching connector Panel Indication Connector Connector Sony Part No 1 D su...

Page 24: ...the B connector have the same signal because the same signal is distributed by internal buffers 1 8 2 Connecting Connector and Cable When connecting cable to connectors on the connector panel at the time of installing or servicing use the following connector cables or equivalents Connectors on BKSI 2044 Matching connector cable Panel Indication Connector Connector cable Sony Part No 1A BNC 75 Ω BN...

Page 25: ...f the cable is broken When SIU 80A 80 operating as the S BUS secondary station A connection example is shown below when the video routing switcher DVS V6464B is used as primary station Primary station Terminate the unused remote connector with a 75 Ω terminator Secondary station Attach a T type bridge to the end of the cable BELDEN 8281 cable and terminate it with a 75 Ω terminator n If terminatio...

Page 26: ...m 30 m using RCC 5G 10G 30G cables BKSI 2042 IDC SERIAL I F CONNECTOR BOARD General Operating temperature 5 C to 40 C 41 F to 104 F Storage temperature _20 C to 60 C _4 F to 140 F Operating humidity 10 to 90 no condensation Dimensions includes the connector panel 301 x 95 x 27 5 mm W D H 117 8 33 4 11 8 inches Mass 0 5 kg 1 lb 2 oz Power requirements 5 V 0 6 A supplied from System Interface Unit S...

Page 27: ...ments 5 V 0 1 A non connection of connectors supplied from System Interface Unit SIU 80A 80 Power consumption 0 5 W Input output S BUS VS BUS BNC type connectors 4 S BUS VS BUS connector 2 connectors uses per 1 channel total 2 channels Others Data transfer rate S BUS 312 5 kbps VS BUS 1250 kbps Data transmission distance S BUS maximum 500 m using BELDEN 8281 cable VS BUS maximum 200 m using BELDEN...

Page 28: ......

Page 29: ... de Sony Corporation Sony Corporation interdit formellement la copie de quelque partie que ce soit de ce manuel ou son emploi pour tout autre but que des opérations ou entretiens de l équipement à moins d une permission écrite de Sony Corporation Das in dieser Anleitung enthaltene Material besteht aus Informationen die Eigentum der Sony Corporation sind Die Sony Corporation untersagt ausdrücklich ...