1-9 (E)
BKSI-2440
.....
Connectors
n
( ) marks show the address on board.
Ref No.
Name
Function
CN100 (A-5)
Factory use only
—
CN500 (A-3)
CN700 (A-3)
CN1200 (A-5)
CN1201 (A-4)
CN1300 (D-1)
CN1301 (C-6)
CN400 (A-2)
Compact flash card
Connects the Compact flash card supplied with the main unit.
.....
LEDs
n
( ) marks show the address on board.
Ref No.
Name
Function
D100 (A-5)
MAIN CPU indicator
Displays the operation status for the MAIN CPU.
Blinks in green:
MAIN CPU is normal.
Blinks in orange: Flash ROM is being written.
Blinks in red:
Communication between route and sub boards is
abnormal, or writing error occurred in Flash ROM.
D600 (A-6)
Root indicator
Lights when this board is used for root controller.
D401 (A-3)
Compact flash card
Displays the operation status for the Compact flash card.
indicator
Lights in green:
Compact flash card is being connected.
Blinks in green:
Compact flash card is in operation.
Blinks in red:
Compact flash card is in preparation to be
connected/released.
No light:
Compact flash card is ready to be relased.
D714 (A-1)
IF CPU indicator
Displays the operation status for the IF CPU.
.
For route board
Blinks in green:
IF CPU is logging in to SMS/GW.
Lights in green:
IF CPU is re-logging in to SMS/GW.
Blinks in orange: IF CPU is logging out from SMS/GW.
Lights in orange: IF CPU is waiting for re-login to SMS/GW.
.
For sub board
Blinks in green:
IF CPU is normal.
ND100, ND101 (A-6)
7-seg indicator
The indication depends on a software to be installed.
*
1
ND700, ND701 (A-1)
*
1: For details about the indication, refer to the file “SETUPE.WRI” in the disc supplied with the Server Management Software BSS-1.