21
Rewriting the Service Mode Status
You need to rewrite the service mode
status so that the input adaptor can
accept HD SDI signals. The following
shows how to do this.
1
Press the MENU/EXIT button on
the monitor.
The main menu appears.
2
To go to the service mode, press
the DEGAUSS and ENTER/
SELECT buttons at the same time.
The service mode status menu
appears.
MENU
EXIT
MENU
STATUS
COLOR TEMP SELECT/ADJ
SYNC SELECT
YPBPR/GBR
16 9/4 3
4 3 MARKER ADJ
FACTORY PRESET
SELECT ENTER
MENU
ENTER
SELECT
DEGAUSS
BTA 1125 N/S
H. SIZE
238 3
MENU
EXIT
ENTER
SELECT
SDI EXIST
0 216
3
Press the MENU/EXIT and
ENTER/SELECT buttons as
needed to display “SDI EXIST 0
216” on the screen.
4
Using the +/
↑
button, change “0”
to “1” in “SDI EXIST 0 216.”
5
Press the DEGAUSS button.
The “WRITE” message appears.
RESET
SDI EXIST
1 216
DEGAUSS
SDI EXIST
1 216
WRITE
(Continued)