LOG SENSE
6.Command Specification
SONY AIT-2 Turbo drive SDX-550V series Ver.1.0
6-27
Parameter Code
Length
Default Cumulative
Default Threshold
0001h Frame Read or Write
4
0
FFFFFFFFh
0002h Main Data SYMN Block Errors CH1
4
0
FFFFFFFFh
0003h Main Data SYMN Block Errors CH2
4
0
FFFFFFFFh
0004h Reserved
4
0
FFFFFFFFh
0005h Reserved
4
0
FFFFFFFFh
0006h Reserved
4
0
FFFFFFFFh
0007h Reserved
4
0
FFFFFFFFh
0008h Total Retry Count (Read Only)
4
0
FFFFFFFFh
0009h C2 un-correctable Block (Read Only)
4
0
FFFFFFFFh
Block_Error_Rate [CH1] = Param0002h/(Param0001h
×
224) [AIT1]
Param0002h/(Param0001h
×
336) [AIT2/AIT3/AIT-E Turbo/AIT-1 Turbo/AIT-2 Turbo]
Block_Error_Rate [CH2] = Param0003h/(Param0001h
×
224) [AIT1]
Param0003h/(Param0001h
×
336) [AIT2/AIT3/AIT-E Turbo/AIT-1 Turbo/AIT-2 Turbo]
6.6.11. Data Compression Transfer Log Page
The page allows the host to monitor the performance of the ALDC compression. The PC field in LOG SENSE
determines whether current cumulative, or current/default threshold values are returned. The page has the following
format:
Table 6-26: Data Compression Transfer Log Page
Bit
Byte
7 6 5 4 3 2 1 0
0
Page Code (39h)
1
Reserved
2
(MSB)
Page Length (58h)
3
(LSB)
4
(MSB)
Parameter Code (n)
5
(LSB)
6
DU (0)
DS (1)
TSD (0)
ETC (0)
TMC (00)
Reserved
LP (0)
7
Parameter Length (4)
8
(MSB) Parameter
Value
11
(LSB)
Data Compression Log Page Fields:
Supported Parameter Codes in this page and their meanings are as follows:
Code Description
0001h
0002h
0003h
0004h
0005h
0006h
0007h
0008h
0009h
000Ah
000Bh
Number of entities written
Number of entities read
Number of records written
Number of records read
Kilobytes to data compression
Kilobytes from data compression
Kilobytes to tape
Kilobytes from tape
Logical entity size
Physical entity size
Uncompressed entities