6.Command Specification
LOG SENSE
6-22
SONY AIT-2 Turbo drive SDX-550V series Ver.1.0
Code
Flag
Type Flag Type
Recommended application client message
Probable cause
2Ch Loader
Hardware C
O
C
The autoloader has a hardware fault:
1. Turn the autoloader off and then on again.
2. Restart the operation.
3. If the problem persists, call the tape drive
supplier helpline.
Check the autoloader users manual for device
specific instructions on turning the device power
on and off.
The loader mechanism
has a hardware fault
that is not mechanically
related.
2Dh Loader
Magazine
O
C
The autoloader cannot operate without the
magazine.
1. Insert the magazine into the autoloader
2. Restart the operation.
Loader magazine not
present
2Eh Loader
Predictive
Failure
O
W
A hardware failure of the changer mechanism is
predicted.
Call the tape drive supplier helpline.
Predictive failure of
loader mechanism
hardware
32h
Lost
Statistics
O
W
Media statistics have been lost at some time in
the past
Drive or library powered
down with tape loaded
33h
Tape
directory
invalid at
unload
O
W
The tape directory on the tape cartridge just
unloaded has been corrupted.
File search performance will be degraded
The tape directory can be rebuilt by reading all the
data.
Error prevented the tape
directory being updated
on unload.
34h
Tape system
area write
failure
O
C
The tape just unloaded could not write its system
area successfully:
1. Copy data to another tape cartridge
2. Discard the old cartridge
Write errors while
writing the system log
on unload
35h
Tape system
area read
failure
O
C
The tape system area could not be read
successfully at load time:
1. Copy data to another tape cartridge
2. Discard the old cartridge
Read errors while
reading the system area
on load
36h
No start of
data
O
C
The start of data could not be found on the tape:
1. Check you are using the correct format tape
2. Discard the tape or return the tape to your
supplier
Tape damaged, bulk
erased, or incorrect
format