13.Appendix F
SONY AIT-2 Turbo drive SDX-550V series Ver.1.0
13-5
LOG SELECT Command (4Ch)
Bit
Byte
7 6 5 4 3 2 1 0
0
Operation Code (4Ch)
1
Logical Unit Number
Reserved
PCR
SP (0)
2
PC Reserved
3
Reserved
4
Reserved
5
Reserved
6
Reserved
7
(MSB)
Parameter List Length
8
(LSB)
9
Unused (00b)
Reserved
Flag
Link
Parameter List Length :
390 byte
Bit
Byte
7 6 5 4 3 2 1 0
0
Page Code (3Eh)
1
Reserved
2
(MSB)
3
Page Length
(LSB)
4
(MSB)
5
Parameter Code
(LSB)
6
DU DS TSD ET
TMC
Reserved
LP
7
Reserved
8
(MSB)
User Data Length
9
(LSB)
10
:
:
User Data
389
Page Length:
386 byte
Parameter Code:
In case of UVN, 0001h
13.8.2.
User Data Length: 380 byte
User Data:
380 byte
13.8.2.1. Procedure of Reading User Data on MIC using LOG SENSE
Command
Example: Steps for reading user partition note added on partition #3.
Input Parameter Code User Partition Note ( for Partition #3), parameter code is 0005h.
In order to read it out, use LOG SENSE twice.
1
st
time : Limit to get user partition size information only.
2
nd
time : Acquire content of user partition note on 2
nd
log sense.