Chapter 6
Maintenance and Troubleshooting
75
Chapter 6
Maintenance and Troubleshooting
Alarm message on monitor screen
Direction
Alarm message on time
counter display
Cause
Key is jammed.
Check the following buttons: EJECT, STOP,
F FWD, REW, PLAY, REC,
˘
,
≥
,
¿
,
÷
, SET
(YES), TC PRESET, MENU, RESET (NO), INPUT
SELECT (VIDEO, AUDIO CH-1 CH-1/2, AUDIO
CH-2 CH-3/4, QSDI), COUNTER SELECT, AUDIO
REC SELECT
Key jammed!
Moisture has been detected.
Keep the power on and wait until this alarm
message disappears.
HUMID!
No cassette in VTR.
Load a cassette.
No Cass.!
Record inhibit plug on the cassette is set to
inhibit.
Set the REC/SAVE switch on the cassette to REC.
REC INHI.!
Remote mode is selected.
Set the REMOTE/LOCAL switch to LOCAL.
REMOTE!
Tape cannot be replayed.
Use a tape having signals recorded in 525/60
format.
625/50 Tape
Use a tape having signals recorded in 625/50
format.
525/60 Tape
Tape end has been detected.
Use a new cleaning tape.
Tape end!
Tape not editable.
Use a tape recorded in DVCAM format.
Not DVCAM!
Use a tape having signals recorded in 525/60
format.
625/50 Tape
Use a tape having signals recorded in 625/50
format.
525/60 Tape
Tape not usable.
Use DVCAM/DV ME (metal-evaporated) tape.
MP Tape!
ILL. Tape!
TC EXTERNAL is selected.
Use the setup menu to set “TC MODE” to “INT
PRESET”.
TC EXT!
TCG REGEN mode is selected.
Use the setup menu to set “TC MODE” to “INT
PRESET”.
REGEN mode!
TCG RUN mode is set to REC RUN.
Use the setup menu to set “RUN MODE” to “FREE
RUN”.
REC RUN!
Alarm messages and associated directions (Continued)