TROUBLESHOOTING
Charging Test
To perform this test use:
-
Phone with the Normal SW (SSW)
-
Dummy Battery connected to Power Supply Channel 1 VBATT
-
Power Supply Channel 1 VBATT instrument settings:
Voltage: 3.0 to 4.2 Volts, according to VBATT row in the Reference Table.
Limiter: 2A
-
Power Supply Channel 2 DCIO/SEPI instrument settings:
Voltage: 5V
Limiter: 2A
Test instructions:
-
Disconnect the DCIO/SEPI Cable between each measurement and wait for phone to
shut down when changing VBATT voltage.
-
Take a note of Current measurements at Power Supply Channel 2 DCIO/SEPI and
Display charging indicator status, X seconds after DCIO/SEPI cable has been inserted
according to Test Time row in the reference table below.
-
Compare test results with the reference table below, tol/-20%.
Reference Table
VBATT x Volt
3.0
3.1
3.2
3.3 3.4 3.5
3.6
3.7 3.8 3.9
4.0
4.1
4.2
Test Time x sec.
15s
15s
25s
25s 25s 25s
25s
25s 25s 25s
25s
25s
40s
DCIO/SEPI
Current mA
220
220
200-400 200 200 200 200 770 770 770
700
430
0
Display indicate
charging
Nothing Nothing
Yes
Yes Yes Yes
Yes
Yes Yes Yes
Yes
Yes
Fully
Charged
Power Supply Channel 1 VBATT must allow reverse current.
If the charging current is Not equal to the reference table go to Charging problems TRS
Guide.
If the charging current is equal to reference table then insert the normal battery and test the
charging current to define if the phone battery is working properly.
Measure the voltage at the battery to define the current level.
If the battery is receiving the right current, then the phone and the battery are working
properly.
SEMC Troubleshooting Manual
Charging Test - ASIC Revision Test
K630 - V640 - K660
ASIC Revision Test
The purpose with this test is to check following items:
-
that the ASICs Revision State is correct
-
Check if communication to and from the ASIC-s is Ok
The following ASICs are tested:
-
D2000 (Anja)
-
N2000 (Vera)
-
N1400 (Bluetooth and FM Radio ASIC)
To perform this test use:
-
Phone with the ITP SW
-
TRS Fixture
-
Power Supply Channel 1 VBATT (Voltage: 3.8V, Limiter: 2A)
-
Power supply Channel 2 DCIO/SEPI (Voltage: 5V, Limiter: 2A)
-
Fault Trace SW choose General – Asic Revisions – Read All
Reference return value can be found in the table below.
ASIC
Description
Part Number
Return Value (hex)
D2000
CPU (Anja)
1200-0186
0x2C8
N2000
Power Management (Vera)
1000-8142
0xC5
N1400
Bluetooth:
Firmware Revision
Chip ID
1200-6182
0x5,0x1
0x0,0x0,0x0,0x0
Will always return 0
on STLC because
Chip ID is not
supported.
N1400
FM Radio
1200-6182
0x800
1215-3608 rev. 1
22
(96)
TROU
B
L
E
S
H
O
OTIN
G