C903
1228-1147 rev. 1
ABOUT
Equipment List
AB
O
U
T
C903 Equipment List
Info: Additional information about the equipment used for TRS can be found in the following
location: CSPN – Repair Instructions – Mechanical – Tool Catalogue – RepairToolsCatalogue.pdf or
matris.xls – C Model Tab.
Troubleshooting Fixture
Location: CSPN – Repair Instructions – Mechanical – Tool Catalogue – RepairToolsCatalogue.pdf
Part number: 1225-3244
Note!
Additional information about the TRS Fixture Kit can be found in the Trouble Shooting
Fixtures Setup Instructions document which is included in this TRS Manual.
Dummy Battery
Location: CSPN – Repair Instructions – Mechanical – Tool Catalogue – RepairToolsCatalogue.pdf
Part number: NTZ 112 533
Note!
The resistance between GND and BDATA should be approximately 120 KOhm.
Instruments
Power Supply Channel 1 (VBATT)
Agilent 6632B or similar
Location: CSPN – Repair Instructions – Mechanical – Tool Catalogue – RepairToolsCatalogue.pdf
Instrument Settings:
Voltage: 3.8 Volt
Limiter: 2.0 A
Note!
Max cable length between the Power Supply Channel 1 VBATT and the dummy battery is 1
metre. The cable must have a capacity for at least 16A.
Power Supply Channel 2 (DCIO/SEPI)
Agilent 6632B or similar
Location: CSPN – Repair Instructions – Mechanical – Tool Catalogue – RepairToolsCatalogue.pdf
Instrument Settings:
Voltage: 5.0 Volt
Limiter: 2.0 A
Oscilloscope
Agilent DSO7052A or similar
Location: CSPN – Repair Instructions – Mechanical – Tool Catalogue – RepairToolsCatalogue.pdf
Digital Multimeter (DMM)
Fluke 83 or similar
Location: CSPN – Repair Instructions – Mechanical – Tool Catalogue – RepairToolsCatalogue.pdf
Note!
The 0, 64 mm Test Probes is recommended by Sony Ericsson when the DMM is in use,
please see Picture 1.
Picture 1
SEMC Troubleshooting Manual
3
(129)