background image

Warranty

iii

CE Conformity

iii

pictures of the product packaging and no�fy the carrier immediately with
all the relevant details of the shipment. Packing materials should be kept for
inspec�on and also for if the product needs to be returned.

The product is shipped with the following equipment so please check to
ensure that you have all of the items below. If anything is missing, please
contact the supplier of your equipment immediately.

If you require a different power lead, please let us know when ordering the
product.

Repairs & Returns

Please contact Sonifex or your supplier if you have any problems with your
Sonifex product. Email [email protected] for the
repair/upgrade/returns procedure, or for support & ques�ons regarding the
product opera�on.

Conformity

The products in this manual comply with the essen�al requirements of the
relevant European health, safety and environmental protec�on legisla�on.

The technical jus�fica�on file for this product is available at Sonifex Ltd.

The declara�on of conformity can be found at:
h�ps://www.sonifex.co.uk/declara�ons

Item

Quality

Product unit

1

IEC mains lead fi�ed with moulded plug

1

Handbook

1

Safety & Installation of Mains
Operated Equipment

There are no user serviceable parts inside the equipment. If you should
ever need to look inside the unit, always disconnect the mains supply
before removing the equipment covers. The cover is connected to earth by
means of the fixing screws. It is essen�al to maintain this earth/ground
connec�on to ensure a safe opera�ng environment and provide
electromagne�c shielding.

Voltage Setting Checks

Ensure that the machine opera�ng voltage is correct for your mains power
supply by checking the box in which your product was supplied. The voltage
is shown on the box label. The available voltage se�ngs are 115V, or 230V.
Please note that all products are either switchable between 115V and 230V,
or have a universal power supply.

Fuse Rating

The product is supplied with a single fuse in the live conduc�ng path of the
mains power input. For reasons of safety it is important that the correct
ra�ng and type of fuse is used. Incorrectly rated fuses could present a
possible fire hazard, under equipment fault condi�ons. The ac�ve fuse is
fi�ed on the outside rear panel of the unit.

Power Cable & Connection

An IEC power connector is supplied with the product which has a moulded
plug a�ached.

The mains plug or IEC power connector is used as the disconnect device.
The mains plug and IEC power connector shall remain readily operable to
disconnect the apparatus in case of a fault or emergency.

The mains lead is automa�cally configured for the country that the product
is being sent to, from one of:

Summary of Contents for Dante AVN-AIO4

Page 1: ...s for AV Installed Sound Broadcast Radio Broadcast TV Multi Channel Dante Audio Interfaces 4 Input 4 Output Dante Interface PoE 8 Input 8 Output Dante Interface PoE 16 Output Dante Interface PoE HANDB...

Page 2: ...ithout the express wri en permission of Sonifex Ltd Unless otherwise noted all names of companies products and persons contained herein are part of a completely fic ous adapta on and are designed sole...

Page 3: ...g 3 9 Showing the Filter Pane 7 Fig 3 10 Filtering Transmi ers 8 Fig 3 11 Filtering Channels 8 Fig 3 12 Simple Rou ng 8 Fig 3 13 Quick Rou ng Before 9 Fig 3 14 Quick Rou ng A er 9 Fig 3 15 Clock Statu...

Page 4: ...line you can increase your product warranty to 2 years and we can also keep you informed of any product design improvements or modifications To register your product please go online to www sonifex co...

Page 5: ...date of despatch the Contract means the quota on these Condi ons of Sale and any other document incorporated in a contract between the Company and the Purchaser This is the en re Contract between the...

Page 6: ...me e At the request and expense of the Purchaser the Company will test the Goods to ascertain performance levels and provide a report of the results of that test The report will be accurate at the me...

Page 7: ...ide the equipment If you should ever need to look inside the unit always disconnect the mains supply before removing the equipment covers The cover is connected to earth by means of the fixing screws...

Page 8: ...electrical and electronic equipment on the environment during their life mes and when they become waste All products manufactured by Sonifex Ltd have the WEEE direc ve label placed on the case Sonife...

Page 9: ...rk connec on for configura on using Dante Controller AES67 opera on Dante Domain Manager compliant 1U 19 rack mount form factor Powered by PoE The sample rate can be configured between the following o...

Page 10: ...e of the front panel are three status LED s and a reset bu on PoE The PoE status LED is illuminated when power over ethernet is available Because PoE is the only power supply source this is essen ally...

Page 11: ...ne inputs and four XLR line outputs are available Fig 2 4 AVN AIO8 Rear Panel On the AVN AIO8 eight locking XLR line inputs and eight XLR line outputs are available Fig 2 5 AVN AO16 Rear Panel On the...

Page 12: ...2 Output Posi ve 3 Output Nega ve Ethernet Connection Fig 2 6 Ethernet Connec on The Ethernet connec on provides PoE and networking capability There are also two status LEDs on the connector The le L...

Page 13: ...ante Controller 3 3 Dante Controller Dante Controller is used to create connec ons between Dante enabled devices on the network This sec on will help you get up and running However for more detailed d...

Page 14: ...Rename Device field the user can change the name that appears in Dante Controller for the device Change the name in the field and click apply The name is then updated in the rou ng grid Channel Label...

Page 15: ...are a large number of devices on a network it could take a while to look through all the transmi ers and receivers to find the right one Therefore filters are available which allow the user to sort th...

Page 16: ...ceivers Typing Commentator into the Filter Receivers field all channels with Commentator in their name are displayed Routing Audio Rou ng audio between two Dante devices is simple Click on the box at...

Page 17: ...their device is a PTP master or a PTP slave A master device provides a clock which all slave devices on a network remain in sync with The master device is selected using the best PTP clock algorithm...

Page 18: ...by default Select Enabled from the dropdown menu to enable this mode This op on will be not be available if the device is part of a Dante domain A warning will be displayed asking you to confirm the...

Page 19: ...P stream has the same prefix as the device you would like to route it to By default the prefix is 69 so the mul cast address of the AoIP stream should be 239 69 X X where the value of X can be any num...

Page 20: ...indow In the example the channels 01 and 02 are added to the AES67 mul cast flow the Create bu on is then clicked The Transmit tab of the device configura on window will show the new mul cast flow in...

Page 21: ...ar in Dante Controller with red text Fig 3 25 Red Device Name Indicates Different Network Subnet Opening the Device View for the device will provide details about the problem Fig 3 26 Problem Details...

Page 22: ...he 192 168 1 X subnet and the computer is on the 10 X X X subnet To correct this edit the computer s IP address In Windows 10 type View Network Connec ons into the search bar Right click the network t...

Page 23: ...86kg Ne 1 89lbs Weight AVN AIO8 AVN AO16 Ne 1 8kg Ne 3 3lbs Audio Input Performance Specifica ons Parameter Line Input Input Impedance 20k balanced 0dBFS Line Up 18dBu balanced Frequency Response 20H...

Page 24: ...www sonifex co uk t 44 0 1933 650 700 f 44 0 1933 650 726 sales sonifex co uk...

Reviews: